Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 

satisfactory operation of this product. Please retain these instructions for future reference.

Warining

Technical data

Please read these instructions carefully before 

commencing any work.

Cables must be protected using suitable conduit 

or plastic trunking.
Waste electrical products should not be disposed 

of with household waste. Please recycle where

facilities exist. Check with your local authority or

retailer for recycling advice.

This unit must be fitted by a competent and 

qualified electrician.

Check the pack and make sure you have all of the

parts 

listed. 

To prevent electrocution switch off at mains supply

This light fitting should be connected to a circuit 

with a 30mA RCD fitted.

before installing or maintaining this fitting.

Ensure other persons cannot restore the electrical

supply without your knowledge.

Install in accordance with IEE Wiring regulations 

and current Building Regulations.

Supply 

Bulb Type:

Voltage: 

240 V~, 50 Hz

LED (18 W)  SMD 2835D  1650lm 6500K - (75531)

LED (36 W)  SMD 2835D  3300lm 6500K - (75532)

LED (45 W)  SMD 2835D  4000lm 6500K - (75533)

LED (55 W)  SMD 2835D  6000lm 6500K - (75534)
The light source of this luminaire is not replaceable; when the light source reaches its end of life 

the whole luminaire shall be replaced.

Conformity with all relevant EC Directive requirements.

The power supply is Double Insulated and does not require connection to an Earth circuit.

Waste electrical products should not be disposed of with household waste.

Please recycle where facilities exist.Check with your Local Authority or

local store for recycling advice.

This product is not suitable for dimming.

Caution! Risk of electric shock!

This product is rated at IP65.

Installation

Max number of interconnect with model: 15 pcs -(75531)  / 12pcs -(75532)

12 pcs -(75533)  / 8pcs -(75534)

Existing fittings must be completely removed before installation of a new product. Before removing the 

existing fitting, carefully note the position of each set of wires.        

 

The ceiling surface must be flat and smooth to ensure a good fit.

 

Note that the switch is turned off before installation.

Attach product to mounting brackets by pushing until 

securely held.

 

Plan the desired layout of this fitting carefully, ensuring the cables will reach the distance between the 

junction box and the light fitting.

 

Avoid locating any cables in positions that would cause a hazard. Position cables and outdoor rated 

junction boxes (not supplied) away from areas where they may be at risk from being cut, trapped 

or damaged. 

 

Refer to the diagram below. Decide on the location of 

the product. Measure the distance between the 

mounting bracket location slots, mark the location 

of the fixing holes on the mounting surface. 

 

Drill holes and fit supplied wall plugs (suitable for 

masonry only - for other surfaces use appropriate 

fixings). 

IP65

We recommend that you use H05RN-F specification 

cable (not supplied) which is an outdoor grade, 

rubber sheathed cable. The mains supply cable 

must have a minimum cross sectional area 

of 1.0mm²

If replacing an existing fitting, make a careful note 

of the connections.

1

2

Model

H1

H2

L

W

A

665mm

1265mm

74mm
74mm

42.5mm 300±10mm

900±10mm

49mm

1565mm 74mm

1200±10mm

75531
75532

75533/75534

42.5mm

49mm

42.5mm

49mm

W

H1 H2

A

L

“click”

“click”

“click”

H05RN-F 2G 1,0 mm²

“click”

not provided

The side that doesn’t have a wire 

must be plugged with plastic cap. 

Prevent water ingress.