background image

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 
satisfactory operation of this product. Please retain these instructions for future reference.

Warning

This light fitting is Double Insulated and 
does not require connection to an Earth 
circuit.

Please read these instructions carefully before 
commencing any work.

This unit must be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure 
other persons cannot  restore the electrical supply 
without your knowledge. If you are in any doubt, 
please consult a qualified electrician.

This light fitting should be connected to a circuit with a 
30mA RCD fitted.

If replacing an existing fitting, make a careful note of 
the connections.

Waste electrical products should not be disposed of 
with household waste. Please recycle where facilities 
exist. Check with your local authority or retailer for 
recycling advice.

This product is rated at IP65.

The entire unit gets hot whilst on for a period of time.

These products should not be fitted to PIR circuits or 
short duration timed switches.

Specification

Voltage: 

240V 50Hz a.c.

Lamp: 

45W LED Module - 4000lm     

IP rating: 

65

Layout

Installation

Wiring

Check that...

•  You have correctly identified the wires.
•  The connections are tight.

•  No loose strands have been left out of the connection 

block.

•  Plan the desired layout of this fitting carefully, 

ensuring the cables will reach the distance between 
the junction box and the light fitting.

•  Avoid locating any cables in positions that would 

cause a hazard. Position cables and outdoor rated 
junction boxes (not supplied) away from areas 
where they may be at risk from being cut, trapped or 
damaged.

•  We recommend that you use H05RN-F specification 

cable (not supplied) which is an outdoor grade, 
rubber sheathed cable. The mains supply cable must 
have a minimum cross sectional area of 1.0mm²

•  Cables must be protected using suitable conduit or 

plastic trunking.

Existing fittings must be completely removed before 
installation of a new product. Before removing the 
existing fitting, 

carefully note the position of each set 

of wires

.

•  Refer to the diagram below. Decide on the location 

of the product. Measure the distance between the 
mounting bracket location slots, mark the location of 
the fixing holes on the mounting surface. 

•  Drill holes and fit supplied wall plugs (suitable for 

masonry only - for other surfaces use appropriate 
fixings).Fix mounting brackets in place.

•  Wire as detailed below.

Having correctly identified the wiring from your existing light fitting, connect to the approved outdoor rated or 
approved double insulated terminal block in the following way:

Отзывы: