Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and
satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This light fitting is Double Insulated and
does not require connection to an Earth
circuit.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure
other persons cannot restore the electrical supply
without your knowledge. If you are in any doubt,
please consult a qualified electrician.
This light fitting should be connected to a circuit with a
30mA RCD fitted.
If replacing an existing fitting, make a careful note of
the connections.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
This product is rated at IP65.
The entire unit gets hot whilst on for a period of time.
These products should not be fitted to PIR circuits or
short duration timed switches.
Specification
Voltage:
240V 50Hz a.c.
Lamp:
45W LED Module - 4000lm
IP rating:
65
Layout
Installation
Wiring
Check that...
• You have correctly identified the wires.
• The connections are tight.
• No loose strands have been left out of the connection
block.
• Plan the desired layout of this fitting carefully,
ensuring the cables will reach the distance between
the junction box and the light fitting.
• Avoid locating any cables in positions that would
cause a hazard. Position cables and outdoor rated
junction boxes (not supplied) away from areas
where they may be at risk from being cut, trapped or
damaged.
• We recommend that you use H05RN-F specification
cable (not supplied) which is an outdoor grade,
rubber sheathed cable. The mains supply cable must
have a minimum cross sectional area of 1.0mm²
• Cables must be protected using suitable conduit or
plastic trunking.
Existing fittings must be completely removed before
installation of a new product. Before removing the
existing fitting,
carefully note the position of each set
of wires
.
• Refer to the diagram below. Decide on the location
of the product. Measure the distance between the
mounting bracket location slots, mark the location of
the fixing holes on the mounting surface.
• Drill holes and fit supplied wall plugs (suitable for
masonry only - for other surfaces use appropriate
fixings).Fix mounting brackets in place.
• Wire as detailed below.
Having correctly identified the wiring from your existing light fitting, connect to the approved outdoor rated or
approved double insulated terminal block in the following way: