background image

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 
satisfactory operation of this product. Please retain these instructions for future reference.

Warning

The power supply is Double Insulated and does not 
require connection to an Earth circuit.

The LED units are Safety Extra Low Voltage and 
must not be earthed.

Please read these instructions carefully before 

commencing any work.

This unit must be fitted by a competent and qualified 

electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

This system operates at Safety Extra Low Voltage 
(12V), via a transformer. Never connect the light 

fittings directly to the mains without using a 
transformer.

Ensure that the supplied transformer is used.

The mains plug must be situated indoors (e.g. house, 
garage, shed) in order to protect it from the elements.

Do not exceed the transformer load. Transformers may 
require a minimum load to operate.

Always disconnect the transformer from the mains 
when installing or maintaining this system.

This system contains non-replaceable parts and 
cannot be serviced. If damage occurs the part should 
be scrapped.

This product cannot be dimmed.

This product is rated at IP44.

Waste electrical products should not be disposed of 

with household waste. Please recycle where facilities 

exist. Check with your local authority or retailer for 
recycling advice.

Specification

The Kit contains:
• 

1 x 12V Indoor plug-in transformer with 5 metre extension lead,

• 

10 x IP44 LED light fittings each with 1 metre of cable attached, 

Layout

•  Plan the desired layout of these fittings carefully, 

ensuring the cables will reach the distances between 
the indoor transformer and each light fitting.

•  Avoid locating any cables in positions that would 

cause a trip hazard. Position cables away from areas 
where they may be at risk from being cut, trapped or 

damaged.

•  Maximum distance between heads is 800mm.

•  Ensure the connectors are accessible for future 

maintenance.

•  The plug-in transformer has no special protection 

against moisture and must be situated indoors.

•  The light units are rated at IP44. Avoid positioning 

head units and conectors in very wet areas.

•  Position the plug- in transformer next to the indoor 

mains outlet socket that the system will connect to. 
Do not plug-in at this stage.

•  After deciding the layout of the light fittings, ensure 

the cables are long enough to connect to the desired 

positions.

•  Drill the mounting holes for the light units taking care 

not to damage any pipes or mains cables beneath 
the mounting surface. These require a 22mm 

clearance hole. 

•  Feed the plug and cables of each light unit through 

the mounting holes and push unit into the hole to 

secure.

•  Connect each LED light to the next LED light 

ensuring the arrows on connectors are facing each 

other and all plugs are fully fitted into the sockets. 

See COnnectors Drawing below.

•  Connect the extension cable to the transformer.

•  Plug the transformer into the mains socket and 

switch on.

Installation

800mm MA

X

End ca

p

30mm diameter LED

22mm diameter
mounting hole

(minimum 30mm depth)

•  We recommend cleaning with a soft dry cloth.
•  Do not use solvents or abrasive cleaners as these 

could damage the finish.

•  To prolong the life and condition of the product, it is 

recommended that periodically it is cleaned using a 
soft cloth followed by the application of a light coating 

of oil, such as WD40.

•  Do not clean the units with a pressure washer.

Connectors

Waste electrical products should not be disposed of with household waste. Please recycle where facilities 
exist. Check with your Local Authority or retailer for recycling advice.

Recycling advice