Warning 

Please read these instructions carefully before commencing any work.

This unit must be fitted by a competent and qualified electrician.

Install in accordance with the IEE Wiring regulations and current Building Regulations.

Check the pack and make sure you have all the parts listed.

To prevent electrocution switch off at the mains supply before installing or maintaining this fitting.

Ensure other persons cannot restore the electrical supply without your knowledge.

If you are in any doubt, please consult a qualified electrician.

If replacing an existing fitting, make a careful note of the connections.

This light should be connected to a circuit with a 30mA RCD fitted.

This  product is suitable for location in or near a marine environment.

The entire unit gets hot whilst on for a period of time, ensure the fitting is mounted out of arms reach.

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice.

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference. 

Layout

Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances between the junction box and the
each light fitting.

Avoid locating any cables in positions that would cause a hazard. Position cables and outdoor rated junction boxes
(not supplied) away from areas where they may be at risk from being cut, trapped or damaged.

We recommend that you use H05RN-F specification cable (not supplied) which is an outdoor grade, rubber sheathed cable.

The mains supply cable must have a minimum cross section area of 1.0mm

2

.

Cables must be protected using suitable conduit or plastic trunking.       

Commissioning

Installation

This light fitting is double insulated and does
not require connection to an Earth circuit.

Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, 

carefully

note the position of each set of wires

.

Note that the switch is turned off before installation.

Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.

After deciding the layout of the light fittings ensure that the cables are long enough to connect to desired positions.

• 

Determine the position of your light fitting taking into account  the entry position of the cable and the 

ARROW

 indicating

    which 

WAY UP

 the base is to be fitted. Make sure there is sufficient cable coming out of the wall to connect to the terminal

    block. Ensure that the mounting surface is solid, preferably a brick or block wall and ensure that there are no other cables
    or pipes beneath the surface.

• Diagram A.

 Fit the 2 threaded posts in the back plate and bring the mains cable through the rubber grommet then use the

    back plate as a template and mark the 2 fixings holes, making sure the back plate is correctly aligned so that the threaded
    bolts are horizontal. Use appropriate fixings to secure the back plate to the wall. 

Ensuring the 

drain hole

 is at the base

   of the mounting box.

• Diagram B.

 Connect the house wiring to the internal terminal block. The cable entry grommet must be securely in place to

    ensure that the water ingress protection is maintained. 

NOTE: This is a Class II fitting and must not be earthed. If you

    have any earth cables make sure that they are connected to each other – to maintain earth continuity throughout your
    property – and wrap the earth terminal and connections in 2 layers of good quality insulation tape and keep them
    away from the terminal connections of the fitting. 

Connect the incoming mains as per the diagram.

Having correctly identified the wiring from your light fitting, connect to the approved outdoor rated external terminal block in
the following way:  

Wiring

SUPPLY

LIGHT FITTING

SWITCHED LIVE

NEUTRAL

BLUE (N)

BROWN (L)

Check that...

You have correctly identified the wires

The connections are tight

Diagram C.

(1)

Diagram A.

Diagram A.

Fixing screws

Fixing screws

Mains cable

Threaded bolts

Diagram B.

Incoming Supply

Internal Cables

Switched Live

Neutral

Brown or Labelled -

 L

Blue or Labelled -

 N

L

N

No loose strands have been left out of the connection block

Reseal the approved outdoor rated external terminal block

Drain hole 

• Diagram C. 

Fit the terminal block onto the post in the back plate and then

    fit the front frame over the 2 threaded bolts in the back plate and secure with
    the 2 threaded nuts. Take care not to trap or strain the internal cables.

• 

Fit the appropriate bulbs into the lamp holders 

NOTE: Never fit bulbs of a

   higher wattage than specified on the label (as this may cause overheating
   and damage the fitting).

 

• 

Replace the bulb covers 

(1)

.

• 

Replace fuse or circuit breaker and switch on. Your light is now ready for use.