background image

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 
satisfactory operation of this product. Please retain these instructions for future reference.

Warning

The power supply is Double Insulated and does not 
require connection to an Earth circuit.

The LED strips are Safety Extra Low Voltage and 
must not be earthed.

Please read these instructions carefully before 
commencing any work.

This unit must be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

This system operates at Safety Extra Low Voltage 
(12V), via a LED driver. Never connect the light fittings 
directly to the mains without using a LED driver.

Ensure that the supplied LED driver is used.

The mains plug must be situated indoors (e.g. house, 
garage, shed) in order to protect it from the elements.

Do not exceed the LED driver load. LED drivers may 
require a minimum load to operate.

Always disconnect the LED driver from the mains 
when installing or maintaining this system.

This system contains non-replaceable parts and 
cannot be serviced. If damage occurs the part should 
be scrapped.

This product cannot be dimmed.

This product is rated at IP20

Waste electrical products should not be disposed of 
with household waste. Please recycle where facilities 
exist. Check with your local authority or retailer for 
recycling advice.

Specification

Dimensions 

8.0mm wide, 2.5mm high, 5m long

Voltage 

240V ~ 50Hz

LED Voltage 

12V d.c.

Lumens 

1260 lm

Layout

which can be stuck to most surfaces.

of 100mm or multiples of 100mm.

ensuring the cables will reach the distance between 
the power supply and the Flexline LED position.

cause a hazard. Position cables and Flexline LED's 
away from areas where they may be at risk from 
being cut, trapped or damaged.

conduit or plastic trunking.

Basic Installation

Specification

The Kit should contain:

indoor mains outlet socket that the system will 
connect to. Do not plug-in at this stage.

ensure that the cable can reach when in the desired 
position.

lengths, by unplugging the four pin connectors. To 
shorten the flexline to a specific length, then it can 
be done in multiples of 100mm. Look for the line on 
the strip with four copper pads, as shown below.

anywhere else on the strip as this will cause the 
Flexline strip to stop working. Please note that once 
cut, these strips can only be rejoined by soldering.

connector on the Flexline strip observing the correct 
polarity (align arrows as shown below).

Отзывы: