background image

SUPPL

Y

NEUTRAL

LIGHT FITTING

BLUE (N

)

EARTH (GREEN/YELLOW)

GREEN/YELLOW

BROWN (L)

SWITCHED LIVE

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory 
operation of this product. Please retain these instructions for future reference.

Warning

This light fitting is Class 1 and must be connected to 
an Earth circuit

Please read these instructions carefully before 
commencing any work.

This unit must be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure other 
persons cannot  restore the electrical supply without 
your knowledge. If you are in any doubt, please consult a 
qualified electrician.

This light fitting should be connected to a circuit with a 
30mA RCD fitted.

If replacing an existing fitting, make a careful note of the 
connections.

Always use the correct type and wattage bulb. Using the 

incorrect wattage bulb will damage the bulb and ballast.

When changing a bulb, always switch off at the mains and 
allow the old bulb to cool down before handling.  Dispose 
of used bulbs carefully and responsibly.

Waste electrical products should not be disposed of with 
household waste. Please recycle where facilities exist. 
Check with your local authority or retailer for recycling 
advice.

This product is rated at IP44.

This product is not suitable for dimming.

This product is not suitable for location in or near a 
marine or sea environment.

The entire unit gets hot whilst on for a period of time.

These products should not be fitted to PIR circuits or short 
duration timed switches. Should you wish to connect this 
unit to a timed system please consult the manufacturer 
before installation.

Specification

Voltage: 

240V 50Hz a.c.

Lamp: 

1 x 10W G24d-1 PLC 2 pin

IP rating: 

44

Layout

Installation

Having correctly identified the wiring from your existing 
light fitting and connect to the connection block inside the 

product in the following way:

Wiring

Check that...

•  You have correctly identified the wires.
•  The connections are tight.
•  No loose strands have been left out of the connection 

block, and all exposed areas of the connection block are 
covered with two layers of insulation tape.

•  Plan the desired layout of this fitting carefully, ensuring 

the cables will reach the distance between the junction 
box and the light fitting

•  Avoid locating any cables in positions that would  

cause a hazard. Position cables and junction boxes (not 
supplied) away from areas where they may be at risk 
from being cut, trapped or damaged

•  Cables in walls must be protected using suitable 

conduit or plastic trunking. 

•  The mains supply cable must have a minimum cross 

sectional area of 1.0mm²

•  This product must only be fitted with the lampholder 

facing upwards.

•  This product has special protection against the ingress 

of moisture and is IP44 rated.

Existing fittings must be completely removed before 
installation of a new product. Before removing the existing 
fitting, 

carefully note the position of each set of wires

.

•  Undo the 3 screws, and remove the front cover (Fig.1). 

Retain screws for future use.

•  Hold the wall back in place and mark the position of the 

holes. Ensure that the product is level.

•  Ensure the wall is capable of holding the weight of the 

product. Take care to avoid damaging any concealed 
wiring and pipes. The correct fixings should be used for 
brick, cavity walls or plasterboard. 

•  Pierce grommet and pass the supply cable through the 

hole in the wall back.

•  Fix the wall back into position using the supplied screws 

(Fog.2) and wire as below.