SUPPL
Y
NEUTRAL
LIGHT FITTING
BLUE (N
)
EARTH (GREEN/YELLOW)
GREEN/YELLOW
BROWN (L)
SWITCHED LIVE
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
This light fitting is Class 1 and must be connected to
an Earth circuit
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure other
persons cannot restore the electrical supply without
your knowledge. If you are in any doubt, please consult a
qualified electrician.
This light fitting should be connected to a circuit with a
30mA RCD fitted.
If replacing an existing fitting, make a careful note of the
connections.
Always use the correct type and wattage bulb. Using the
incorrect wattage bulb will damage the bulb and ballast.
When changing a bulb, always switch off at the mains and
allow the old bulb to cool down before handling. Dispose
of used bulbs carefully and responsibly.
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling
advice.
This product is rated at IP44.
This product is not suitable for dimming.
This product is not suitable for location in or near a
marine or sea environment.
The entire unit gets hot whilst on for a period of time.
These products should not be fitted to PIR circuits or short
duration timed switches. Should you wish to connect this
unit to a timed system please consult the manufacturer
before installation.
Specification
Voltage:
240V 50Hz a.c.
Lamp:
1 x 10W G24d-1 PLC 2 pin
IP rating:
44
Layout
Installation
Having correctly identified the wiring from your existing
light fitting and connect to the connection block inside the
product in the following way:
Wiring
Check that...
• You have correctly identified the wires.
• The connections are tight.
• No loose strands have been left out of the connection
block, and all exposed areas of the connection block are
covered with two layers of insulation tape.
• Plan the desired layout of this fitting carefully, ensuring
the cables will reach the distance between the junction
box and the light fitting
• Avoid locating any cables in positions that would
cause a hazard. Position cables and junction boxes (not
supplied) away from areas where they may be at risk
from being cut, trapped or damaged
• Cables in walls must be protected using suitable
conduit or plastic trunking.
• The mains supply cable must have a minimum cross
sectional area of 1.0mm²
• This product must only be fitted with the lampholder
facing upwards.
• This product has special protection against the ingress
of moisture and is IP44 rated.
Existing fittings must be completely removed before
installation of a new product. Before removing the existing
fitting,
carefully note the position of each set of wires
.
• Undo the 3 screws, and remove the front cover (Fig.1).
Retain screws for future use.
• Hold the wall back in place and mark the position of the
holes. Ensure that the product is level.
• Ensure the wall is capable of holding the weight of the
product. Take care to avoid damaging any concealed
wiring and pipes. The correct fixings should be used for
brick, cavity walls or plasterboard.
• Pierce grommet and pass the supply cable through the
hole in the wall back.
• Fix the wall back into position using the supplied screws
(Fog.2) and wire as below.
Fig 2.
Fig 1.