background image

Warning 

This is a Class 1 product and must be earthed.

Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons cannot
restore the electrical supply without your knowledge.
This light fitting should be connected to a circuit with a 30mA RCD fitted.
If replacing an existing fitting, make a careful note of the connections.
This product is not suitable for location in or near a marine environment.

This system contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped.

 

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with

your local authority or retailer for recycling advice.

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory

operation of this product. Please retain these instructions for future reference. 

Layout

Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances between connector and
the light fitting.
Avoid locating any cables in positions that would cause a hazard. Position cables and junction boxes
(not supplied) away from areas where they may be at risk from being cut, trapped or damaged.
The mains supply cable must have a minimum cross section area of 1.0mm

2

Cables must be protected using suitable conduit or plastic trunking.
This product has special protection against the ingress of moisture and is IP65 rated.     

Installation

Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully

note the position of each set of wires.
Note that the switch is turned off before installation.
This product must be mounted onto a concrete base or paving slab. It should be not directly installed in the soil.

• 

Prepare the hole for the root kit. The foundation should be a minimum of 175mm diameter with a minimum depth 150mm.

• 

Pour cement into the hole, ensuring the cement is finished level and smooth.

• 

Ensure a suitable amount of supply cable is exposed so the fitting can be correctly wired after the foundation has been

   prepared. Insert the anchor bolts into the wet cement ensure the top plate is resting level on top of cement with the
   threads exposed.

• Wire as detailed wiring.
• 

Locate the base of the bollard over the anchor bolts and secure in place using the supplied spring washers.

• Ensure that the cable is not snagged. 
• Replace fuse or circuit breaker and switch on. Your light ready now for use.

root kit

Min.Ø175mm

Min.150mm

This product is colour changing and can be either warm white (3000K) or cool white (4200K) or

daylight white (6000K), the default setting is cool white (4200K).  

Before installing, need unscrew 3 screws to find out the switch located on head of the lamp body then choose your

preferred colour by using the switch.

This product is colour changing and can be either

warm white (3000K) or cool white (4200K) or

daylight white (6000K), the default setting is

cool white (4200K).  

Before installing, need unscrew 3 screws to find out the 

switch located on head of the lamp body then choose your

preferred colour by using the switch.

Отзывы: