Warning 

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory

operation of this product. Please retain these instructions for future reference. 

These products should not be fitted to PIR circuits or short duration timed switches.

Install in accordance with the IEE Wiring regulations and current Building Regulations.

This is a Class 1 product and must be earthed.

Any faulty, broken or damaged modules should be replaced immediately.

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice.

Do not use Megger or similar high voltage instruments. Due to the fact this Emergency pack contains electronic
components that maybe damaged by high test voltages, they must be disconnected from the circuit before testing.
To prevent damage to the Emergency pack, do not mix with conventional magnetic ballasts on the same electrical circuit.

Please read these instructions carefully before commencing any work
This unit must be fitted by a competent and qualified electrician.

Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons
cannot restore the electrical supply without your knowledge.
This light fitting should be connected to a fused circuit.

If replacing an existing fitting, make a careful note of the connections.

Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances between each light fitting.
Avoid locating any cables in positions that would cause a hazard. Position cables away from areas where they may be
at risk from being cut, trapped or damaged
Cables in walls must be protected using the suitable conduit or plastic trunking.
The mains supply cable must have a minimum cross section area of 1.0mm

2

.

Layout

Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, 

carefully

note the position of each set of wires.

Note that the switch is turned off  before installation.
After deciding the layout of the light fittings ensure that the cables are long enough to connect to desired positions.  
• Undo the screws at the right hand end of the fitting and lift cover off and set aside.

• Pull the cable through the cable entry hole and wire as detailed Wiring Diagram.

Installation

• Using the unit as a template mark the position of the fixing holes. Take care to avoid damaging any concealed wiring and pipes.
   The correct fixings should be used, depending upon the surface to be mounted.

• Remove the plastic plug from one of the cable entry holes.

• Slide out the front panel.

Wiring

Having correctly identified the wiring from your existing light fitting, Pull the wire through hole and connect to the connetion
block inside the product in the following way:

Check that...

•  You have correctly identified the wires.
•  The connections are tight.
•  No loose strands have been left out of the connection block.

Maintained Wiring:

PERMANENT LIVE (L1)

NEUTRAL

EARTH  (GREEN/YELLOW)

SWITCHED LIVE (L2)

NEUTRAL TERMINAL

LIVE TERMINAL

EARTH TERMINAL

SUPPLY

LIGHT FITTING

• This unit works in maintained mode. the lamp can be switched separately on or off. The unit will charge automatically. The
   lamp remains on when the supply is interrupted.  
• Remove the link from between the terminals marked "SW" and connect cables to and from switch.
• Replace fuse or circuit breaker and switch on. Ensure that the source is mains (220-240V~ 50Hz).  
• Verify that the LED is illuminated; this confirms that the batteries are charging.  
• Charge the battery for at least 24 hours before first use.  
• If the LED is not illuminated the there may be A.C. supply, the battery has not been connected properly or the internal circuit
   may have failed.  
• The battery should be re-charged and checked every three months.  
• The battery should be discharged and the duration of the lamp in emergency mode checked every six months.

• This product comes with 3 different arrow slides. Slide in chosen slide. Refit end panel and screws.
• Replace fuse or circuit breaker and switch on. Your light is now ready for use.

Commissioning

Operation