background image

Warning 

This is a Class 1 product and must be earthed.

Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current
Building Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before
installing or maintaining this fitting. Ensure other persons cannot
restore the electrical supply without your knowledge.

Installation

Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, 

carefully

note the position of each set of wires.

Note the power at the fuse board and the luminaire must be switched off before installation or maintenance.

Layout

This track system can be extended to a variety of different configurations using accessories such as left bends,
right bends, T jucntions, X junctions and flexible joints.

Track Accessory:

TJunction

X Junction

Dead End

Bend

This light fitting should be connected to a fused circuit.  
If replacing an existing fitting, make a careful note of the connections.
Only to be installed outside arms reach.
This track is suitable for dimming. But the fittings with low voltage
lamps are not suitable for dimming. Care must be taken to only use
the same type of fitting that is able to be dimmed, and that the
dimmer wattage must not be exceeded.
Waste electrical products should not be disposed of with household
waste. Please recycle where facilities exist. Check with your local
authority or retailer for recycling advice.

108.0mm

35.0mm

35.5mm

79.5mm

294.0mm

35.0mm

35.0mm

108.0mm

108.0mm

35.0mm

16.5mm

183.0mm

183.0mm

35.0mm

35.0mm

108.0mm

183.0mm

40.0mm

40.0mm

43.0mm

35.0mm

182.0mm

1000.0mm
2000.0mm

3000.0mm

35.0mm

• Plan the track layout and and decide accessories
   needed before fixing anything to the ceiling.
• The maximum power per run of track is
   1KW (1000W).

• Mark the first hole position and fit the screw in
   position as shown.
• Feed the screw through the keyhole slot, and
   slide into position. Mark the position of the
   second hole.
• Locate the track and fit the second screw into
   position.
• If fitting accessories, remove the end cap, and
   push them firmly home. Fit extra lengths of
   track as required.

• Ensure the ceiling is capable of holding the
   weight of the track and products. Take care to
   avoid damaging any concealed wiring and pipes.
   The correct fixings should be used for brick,
   cavity walls or plasterboard. 

Connection

• The track accessories are provided with earth connection points on both sides.
• When offering the accessory to the track, verify which tab needs to be removed.
  (See left hand diagram). 

• To remove the tab, grasp firmly with a pair of pliers and lever back. 
• The tab should snap cleanly off. (See right hand diagram). 
• Locate the accessory in the track and push home.

End view of track

Earth Conductor

Remove One or Other Tab

Marked in Grey

Remaining Earth tab needs

to be inserted into Earth

conductor to ensure Earth

continuity.   

Thank you for purchasing this light fitting. Please read the instruction carefully before use to ensure safe and satisfactory

operation of this product. Please retain these instruction for future reference. 

23W

34W

Products:

• Push the switch on the light from OFF to ON.

• Locate the product in the track with the
   connections in the slot. Don’t loosen your hand,
   Push the buckle tab in place to fix the light in the
   track firmly.

• Replace fuse or circuit breaker and switch on.
   Your light is now ready for use.

200mm

146mm

Ø79mm

197mm

140mm

Ø69mm

15W

160mm

110mm

Ø54mm

101630 / 101631 / 101632 / 101633

101634 / 101635 / 101636 / 101637

101626 / 101627 / 101628 / 101629

Push up

Push the buckle tab to

the right in place

90º

330º

Push the switch from OFF to ON

Отзывы: