ENGLISH
13
uSINg THE STEAmER
The Combi Heater includes a Steamer NS with a watertank. It produces steam where
there is anough water in the tank. To ensure ideal humidity, the sauna temperature should
be between 40 and 50º C, and the steamer should be left on for about 30 minutes to pre-
heat the sauna and produce sufficient amount of steam before starting bathing.
fILLINg THE wATER TANK
Water can be poured through the openings underneath the scent basins or by removing
the steamer cover first (See page 9). If water in the tank exceeds the maximum mark
on the level indicator, water from the indicator tube end might spill on the floor. The
water level can easily be monitored through the water level indicator. If FILL appears on
the external control unit’s display, cold household tap water shall be poured through the
openings underneath the scent basins by carefully removing the scent basins.
CAuTIoN:
Streamer cover and scent basins are very hot if the heater is in use. Do not
touch them by bare hand. Always before turning on the steamer, make sure that sufficient
amount of water is in the tank.
Low wATER LEVEL
The Combi Heater has a low water detection system which reminds to refill water before
the steamer tank runs dry. To avoid the activation of the low water detection system, refill
water once the water level reaches the REFILL mark on the water level indicator tube. If
no water is refilled at that point, the low water detection system will automatically turn
off the steamer heater and a FILL message is displayed together with a buzzer tone on
the external control unit. Observe caution while refilling water as the steamer tank is still
hot. After refilling water, the steam generator heater turns on again after a short while.
If no water is refilled upon the FILL message appears on the display of the control unit,
the steamer will turn on again after a few minutes. The FILL message is repeatedly dis-
played until water is filled in the tank or the unit is turned off. In order to preserve the
heating plate and life span of the combi heater avoid “dry boiling” of the steamer tank.
fILLINg THE wATER CompARTmENT
•
Fill the Tank by pouring water through the holes designated for the Scent Basins.
•
The amount of water poured can be monitored using the Water Level Indicator.
•
The water should not exceed the maximum marking on the Level Indicator
•
If “FILL” is displayed on the external control unit, refill the Water Tank. Be careful
in removing the Scent Basins during bathing, as they will be hot to touch. Do not
attempt to remove the Steamer Cover, as it will be extremely hot to touch.
•
Always make sure that there is a sufficient amount of water in the Water Tank before
using the Steamer.
uSINg THE STEAmER wITH buILT-IN AuTomATIC REfILL SySTEm
•
The Combi Heater is equipped with an automatic water refilling system that makes
it possible to produce the steam without refilling water manually.