SUOMI | ENGLISH
9
A
B
A
B
A
B
A
A
45 max. 700
100
125
PNX3-45NS
PNX3-60NS
125
PNX3-75NS
150
1900
1900
1900
1900
PNX3-90NS
150
150
150
175
1900
2100
2100
2100
PNX6-105NS
150
1900
PNX6-90NS
PNX6-120NS
PNX6-150NS
PNX6-180NS
Kuva 2
Fig. 2
HEATER IN INSTALLATION
The heater can be placed wherever in the sauna, but for safety and convenience, follow
the minimum safety distances as provided below (See page 9). Follow the cubic
volumes given in the Technical Data (See page 22). Do not install the heater to the
floor or wall niche. Do not install more than one heater in a sauna room unless you follow
the special instructions for twin-heater installations. In most countries, there is a law that
requires heaters to be screwed to the floor.
The heater gets very hot. To avoid the risk of accidental contact with the heater, it is
recommended that a heater guard be provided.
The cable used for sauna wiring must be HO7RN-F type or its equivalent. A certified
electrician must do the installation of the heater to ensure safety and reliability. Improper
electrical connection can cause electric shock or fire. Refer to the electrical diagram (See
NOTE!
Please refer to the control unit
manual for maximum power
rating. Check control’s maximum
capacity if additional contactor
unit is needed.
HUOM!
Tarkista ohjauskeskuksen
teholuokka ohjauskeskuksen
käyttöohjeesta. Tarkista ohjaimen
maksimikapasiteetti ja hanki
tarvittaessa lisäkontaktoriyksikkö.
Jos kiuas on asennettu
Minimum safety distances (mm)
Minimisuojaetäisyydet (mm)