NOTE
IF
NOT
USING
SAWO INNOVA CONTROL
Transfer the jumper from
“a and U
B
” to “a and Level
” if NOT using SAWO
Innova Control.
electrical wirinG and installation
A certified electrician must do the installation of the heater in accordance with applicable
local regulations to ensure safety and reliability of electrical connections. Improper elec-
trical connections can cause electric shock or fire. The connection cable must be of rubber
cable type H07RN-F or its equivalent.
NOTE: Using a PVC-insulated wire as connection cable for the Combi Heater is not allowed
because this material easily becomes brittle when subjected to heat.
installation of external control unit and sensors
Innova Control Unit utilizes two sensors to power up the Combi heater. One is the Pri-
mary Temperature Sensor (TS1) and the other one is either the Secondary Temperature
Sensor (TS2) or the Temperature and Humidity Sensor (T/H). If the heater is placed
less than 200 mm from the wall, TS1 needs to be mounted on the wall above the heater
and must have a distance of 150 mm from the ceiling. However, if the heater is placed
more than 200mm from the wall, TS1 must be mounted to the ceiling over the heater,
as shown in the illustration. TS2 or T/H should be mounted on the wall opposite to the
heater and must have a distance between 300mm from the ceiling up to 1300mm from
the floor. See further details from control panel manual.
1200
1900
150
155
380
260
65
25
5
155
380
260
Wall Mounting Rack Installation
Installation Wandmontageträger
Lämpötilatunnistinten sijainti
Safety Sensor Location
MNC-30NS
MNC-36NS
R1 = Lämpötilakytkin 1
R2 = Lämpötilakytkin 2
L = Turvakytkin
H# = Vastus - Kiuas
HS = Vastus - Höyrystin
Kuva 8
Fig. 8
Kuva 9
Fig. 9
KYTKENTÄKAAVIO
ELECTRICAL DIAGRAM
R1 = Temperature Regulator 1
R2 = Temperature Regulator 2
L = Temperature Limiter
H# = Sauna Heating Element
HS = Steamer Heating Element