othEr possiblE problEms
• The control unit is working fine, but the heater does not turn on. Check the elec
-
tricity supply to the heater. Check that the wires for the sensors are placed into the
correct terminals in the control unit.
•
Heater doesn’t turn on and main switch in heater is in “ON” position. Check that
terminals N2in and N are interconnected with a jumper wire. Check also that fuse F1
(near transformer) is tightly in fuse holder.
•
User presses a button and “----“ is shown in the display. This indicates that the key
pad is locked. Unlock the buttons by pressing up and down arrow keys at the same
time for more than 5 seconds. A high beep will confirm the activation and the deacti
-
vation.
•
Door open symbol is displayed with high warning tone, when door sensor is not
installed. - Check that door switch terminals are connected with each other by wire
in the power controller (see page 16). Note that the connections is not present in
the drawing.
notE!
Only incandescent light bulbs are allowed to use with Innova sauna controller. Light
fixtures using electronic transformers for example LED lights, compact fluorescent
lights and other similar lights are not compatible with Innova sauna controller.
Damages caused by connecting these non-compatible lights are not covered by
warranty.