- 19 -
8. Trouble shooting
Fault
Possible cause
Action
Interior not cold
Compressor not
working
No power supplied
Check if power is supplied to
electronic unit.
Battery in poor condition.
Check fuse.
Defrost evaporator.
(see 7.2 Defrosting)
Faulty electronic unit.
Electronic unit failure
Check polarity of connectors
and cables.
Ambient temperature too
high.
Keep refrigerator sufficiently
ventilated.
Insufficient ventilation Frost
on evaporator
Condenser clogged
Clean condenser.
Error message will be displayed if the voltage of the battery is low or in the event of any
malfunctions- (see next table).
When error message is displayed, the unit will be on "standby mode".
Operations will stop.
Do not use conventional glass tube fuses. Use only those
designed exclusively for ENGEL refrigerator and distributed
through its dealers.
CAUTION