5
5
OPERATION
To start your refrigerator, set the thermostat control knob to "ON". Your refrigerator
should start operating. The interior should start getting cool to touch within a few
minutes.
PROTECTION SYSTEM
The D.C. power cord is made for negative (-) ground system. Your refrigerator has a
high current protection system incorporated in the electronic circuit to prevent
damage to its power supply, which may occur due to a reverse connection.
If your refrigerator does not operate and the power lamp does not go on, you may
have:
- connected the refrigerator with the incorrect polarity
- blown a fuse in the cigarette lighter plug
- have insufficient voltage from the power source
or
- a problem may exist in the inverter, so call your ENGEL dealer for advice.
CAUTION
FOR MODELS MT17F-U1 and MT27-U1 and MT35F-U1 and MT45F-U1
A fuse is located in the cigarette lighter plug body of the D.C. cord (provided with the
refrigerator), and if the fuse blows, replace the glass fuse with a new 10 Amp fuse.
DIAL SETTING
Refrigerating temperature can be controlled by means of the thermostat control
knob. The interior temperature drops as the knob position is changed from "1"
("REFRIGERATOR") to "5" ("FREEZE"). In this way, interior temperature can be
regulated freely.
When it is desired to preserve frozen food, set the thermostat control knob at "3, 4 or
5" ("FREEZE"). To switch off your refrigerator, set the thermostat control knob to
"OFF". The knob does not turn clockwise beyond "5" ("FREEZE"). For efficient
operation, regulate the temperature according to the types of food stored.