14
1. SAFETY INFORMATION
For your safety and correct
operation of the appliance,
read this manual carefully before
installation and use. Always keep
these instructions with the appli-
ance even if you move or sell it.
Users must fully know the oper-
ation and safety features of the
appliance.
The wire connection has
to be done by specialized
technician.
• The manufacturer will not be
held liable for any damages re-
sulting from incorrect or improper
installation.
• The minimum safety distance
between the cooker top and the
extractor hood is 650 mm (some
models can be installed at a lower
height, please refer to the para-
graphs on working dimensions
and installation).
• If the instructions for installation
for the gas hob specify a greater
distance, this must be respected.
• Check that the mains voltage
corresponds to that indicated on
the rating plate fixed to the inside
of the hood.
• Means for disconnection must be
incorporated in the fixed wiring in
accordance with the wiring rules.
• For Class I appliances, check
that the domestic power supply
guarantees adequate earthing.
• Connect the extractor to the
exhaust flue through a pipe of
minimum diameter 120 mm. The
route of the flue must be as short
as possible.
• Regulations concerning the dis-
charge of air have to be fulfilled.
• Do not connect the extractor
hood to exhaust ducts carrying
combustion fumes (boilers, fire
-
places, etc.).
• If the extractor is used in conjunc-
tion with non-electrical applianc-
es (e.g. gas burning appliances),
a sufficient degree of aeration
must be guaranteed in the room
in order to prevent the backflow
of exhaust gas. When the cooker
hood is used in conjunction with
appliances supplied with energy
other than electric, the negative
pressure in the room must not
exceed 0,04 mbar to prevent
fumes being drawn back into the
room by the cooker hood.
• The air must not be discharged
into a flue that is used for ex
-
hausting fumes from appliances
burning gas or other fuels.
• If the supply cord is damaged,
it must be replaced from the
manufacturer or its service agent.
• Connect the plug to a socket
complying with current regula-
tions, located in an accessible
place.
• With regards to the technical and
safety measures to be adopted
for fume discharging it is importat
to closely follow the regulations
provided by the local authorities.
EN