Savi 3013 Savi Note Скачать руководство пользователя страница 2

INSTALLATION INSTRUCTIONS

SAVI NOTE Underwater LED Light

READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

 CAUTION!  SAFETY PRECAUTIONS

TURN OFF MAIN POWER TO LIGHT BEFORE INSTALLATION 

SAVI NOTE is a low voltage light and should NEVER be electrically connected to a power source other than a SAVI 

M4 controller.  Failure to comply will either damage or destroy SAVI NOTE and VOID the Warranty.

Product   WATTS  AMPS   MINIMUM CONDUIT LENGTH

A Division of Next Step Products

9400  SOUTHRIDGE  PARK  COURT  SUITE  200 

 

ORLANDO,  FLORIDA  32819  USA

Tel:  407.855.5630 

     

Fax:  407.210.8679 

    

nextstepproduct.com

STEP 1

   The light 

 must be installed in 

the 

wall of the pool (or 

water feature) with the top of the lens opening not less than 4 
inches (10.16cm) below the normal water level of the pool.

STEP 2

STEP 3

read the  into the wall  until

 

it

 

is

Using enclosed Lens Key, thread the light into the wall fitting until it is snug.  Please 

provide Pool Owner with minimum of 1 key upon job completion (see winterization 

clause above)

NOTE: Requires the use of a 1-1/2” threaded wall 

NOTE: Make sure all protective coverings have been removed.

4” MIN. FROM WATER 
LEVEL TO TOP OF LENS

1.5” THREADED WALL FITTING

1.5” dia. Pipe

1” min. Pipe

Sweeps ONLY

No 90 degree bends

4” MIN. FROM WATER 
LEVEL TO TOP OF LENS

Allow 18” - 24”

slack for 

Service Loop

Tighten

NOTE: 

All lights 

must be directly 

wired to M4 control

NOTE: 

 

Check with Local Building 

 as to what conduit/pipe is acceptable for usage.

1.5” Pipe through bond beam for a minimum of 14” then 1” conduit min. beyond 

with sweeps / no 90 degree bends. We highly recommend the use of 1

.5"

 pipe 

throughout the entire width of the bond beam. NOTE: Use of 1.5” pipe with 14” 

min. length will accommodate all SAVI Lighting nicheless products.

 Minimum 

1.5" conduit length is 7".

Winterization Clause

Pool Water Level must be drained down 12” below light(s) position in pool wall.

 

We also highly recommend that the lights be loosed from their wall 

 to 

allow drainage of water that might have accumulated within conduit.  Consult 

your local Swimming Pool Professional for proper local area winterization 

processes.

 At NO TIME should there be water removed from the pool without 

checking ground water tables.

Small Gasket

Large Gasket

Flat Gasket

NOTE:

 For Vinyl wall Fittings use both rubber gaskets.

For Gunite and Fiberglass remove the Small 

gasket and use the Large one only.

4” MIN. FROM WATER 
LEVEL TO TOP OF LENS

Vertical Installation for

Benches, Swimouts and 

Fountains

SAVI M4 Controller

Conduit to M4

1. To prevent electrocution and/or death make sure power is off at the breaker.
2. Avoid touching/installing the M4 controller box during electrical storms. Death

or serious injury may result due to lightning surges through the system.

3. Be sure to check local electrical codes for grounding electrical boxes via

the approved method (internal conduit ground, external box ground wire to

 

grounding rod, etc.)

4. Use approved conduit routed by approved methods to conduit fittings on the

box.

5. For DMX based units, do not install data cables in the same conduit as power

cables to prevent communication problems.

6. Be sure the mounting surface is able to support the load of the controller. Use

 

all 

four mounting holes to secure the controller.

7. There are no customer serviceable components inside the M4 controller. Only

qualified electricians should open the box for installation of the power and LED

 

accessories connections. All connections should enter through an approved

 

conduit method.

8. LED accessories are low voltage and should never be electrically connected

to any power source other than the appropriate M4 controller connector (J5

 

to 

J8). Wires must be connected properly to avoid permanently damaging the

 

LED 

accessory.

WARNING

2013 SERVICABLE

SAVI NOTE  14      1.2               7"

Products are available with 30,50,100 & 150ft cords

Pull the 

4

 conductor electric cord throught the conduit inlet of the wall 

fitting, into the conduit and up to the location

 

of the M4 controller.  Cut 

off the excessive cord after allowing for a service loop.  Pull light snug 

into the wall fitting.  THIS PRODUCT DOES NOT ALLOW FOR THE 

USE OF A JUNCTION BOX INSTALLATION.  ALL LIGHTS MUST BE 

DIRECTLY WIRED TO THE M4 COTNROLLER.

Содержание 3013 Savi Note

Страница 1: ...an or a qualified pool professional in accordance with the National Electric Code NEC or the Canadian Electric Code CEC CSA C22 1 All applicable local installation codes and ordinances must also be ad...

Страница 2: ...conduit Consult your local Swimming Pool Professional for proper local area winterization processes At NO TIME should there be water removed from the pool without checking ground water tables Small G...

Страница 3: ...he light eminating but for just a slice of light that is broad but thin An incredible effect for illuminating but without spilling light all over DIAMOND WOW want to really create something special Th...

Страница 4: ...seconds Turn back on and proceed to Step 1 OPERATING THE LIGHT 7 To move to the next color mode Turn the lights off for 1 2 seconds and turn back on Repeat until desired color mode is found Example I...

Страница 5: ...age supply or poor connection to light NOTE In most situations problems come down to main faults improper voltage supply improper wiring gauge improper poor wiring connections internal to M4 or the li...

Страница 6: ...any air bubbles quickly remove from water bubbles appear as it indicates the seal is not water tight Retighten the screws and test for bubbles again STEP 5 Reset the fixture into the wall fitting and...

Страница 7: ...n the event of a defect in material or workmanship during the warranty period the Company will repair or replace at its own discretion its products under the conditions of the warranty A complete list...