Part No. 001123, 16-m05-2018

Vuelift Planning Guide

Purpose of This Guide

This guide assists architects, contractors, and lift professionals to incorporate the Vuelift 
Residential Elevator into a residential design. The design and manufacture of the Vuelift Elevator 
meets the requirements of the following codes and standards:
• ASME A17.1/CSA B44 2000, Section 5.3
• ASME A17.1/CSA B44 2004, Section 5.3
• ASME A17.1 2004, Addendum 2005, Section 5.3
• ASME A17.1/CSA B44 2007, Section 5.3
• ASME A17.1/CSA B44, Addendum 2008, Section 5.3
• ASME A17.1/CSA B44 2010, Section 5.3
• ASME A17.1/CSA B44 2013, Section 5.3
• ASME A17.1/CSA B44 2016, Section 5.3
• ASME A17.1 1996, Part 5
We recommend that you contact your local authority having jurisdiction to ensure that you 
adhere to all local rules and regulations pertaining to residential elevators.

IMPORTANT: 

This Planning Guide provides nominal dimensions and specifications useful for the 

initial planning of a vertical platform lift project. Dimensions and specifications are subject to 
change without notice due to continually evolving code and product applications.

Before beginning actual construction, please consult Savaria or the authorized Savaria dealer in 
your area to ensure you receive your site-specific installation drawings with the dimensions and 
specifications for your project.

Visit our website for the most recent Vuelift drawings and dimensions.

How to Use This Guide

1

Determine your client’s intended use of the lift.

2

Determine the local code requirements.

3

Determine the site installation parameters.

4

Determine the cab type and hoistway size requirements.

5

Plan for electrical requirements.

Revision History of This Guide

December 

4

, 2017 - Initial 

release

December 

14

, 2017 - Added Electrical Requirements section on page 9 (round) and page 25 

(octagonal)

January

 

31

, 2018 - Added drawing

s

 for Type 2, Octagonal, Glass on pages 38 to 43

March

 

8

, 2018 - Revised Noise Level spec in Specifications tables on pages 6 to 22

March

 

23

, 2018 - Added dimensions for controller box and UPS on pages 

21 and 4

5

March

 

29

, 2018 - Revised drawing on page 42

May

 

7

, 2018 - 

Added

 wheelchair plan views on pages 21 and 46

May

 

14

, 2018 - 

Added

 notes to wheelchair plan views on pages 21 and 46

May

 

16

, 2018 - 

Added

 note on pages 22 and 47 stating that a remote controller cannot be more 

than 50 feet away from the top of the unit in order for the cable to reach

Содержание Vuelift

Страница 1: ...Vuelift RESIDENTIAL ELEVATOR PLANNING GUIDE Applicable Codes ASME A17 1 CSA B44 Safety Code for Elevators and Escalators Section 5 3 Private Residential Elevators Part No 001123 16 m05 2018 ...

Страница 2: ...sted on the front cover of this Planning Guide Please consult Savaria or the authorized Savaria dealer in your area for more specific information pertaining to your project including any discrepancy between referenced standards and those of any local codes or laws The dimensions and specifications in this Planning Guide are subject to change without notice due to product enhancements and continual...

Страница 3: ...applications Before beginning actual construction please consult Savaria or the authorized Savaria dealer in your area to ensure you receive your site specific installation drawings with the dimensions and specifications for your project Visit our website for the most recent Vuelift drawings and dimensions How to Use This Guide 1 Determine your client s intended use of the lift 2 Determine the loc...

Страница 4: ... Distances 11 Drywall and Painting 11 Load Calculations Round 12 Drawings Round 13 Chapter 2 Octagonal Elevator Acrylic or Silica Glass 22 Specifications Octagonal 23 Safety First Octagonal 25 3 5 rule code prior to 2016 25 3 4 4 rule code 2016 and after 25 Electrical Requirements Octagonal 26 Provisions By Others Octagonal 27 General 27 Dimensions 27 Structural 27 Electrical 27 Entrances 27 Site ...

Страница 5: ...5 Part No 001123 16 m05 2018 Vuelift Planning Guide Chapter 1 Round Elevator Acrylic ...

Страница 6: ...30A 230 V single phase 50 60 Hz Cab lighting 15A 115V single phase 50 60 Hz Suspension Type Galvanized aircraft cable 2 x 3 8 diameter Construction IWRC 7 x 19 RHRL Nominal strength 14 400 lb 6 545 kg Weight of ropes 0 243 lb ft 3 616 g cm Travel cable weight 0 228 lb ft 3 393 g cm Drive train Type Winding drum Motor 1 5 HP with integrated brake Transmission Ultra low vibration 3 stage right angle...

Страница 7: ...ons Type 1 2 3 Optional colors White Texture White PX521W859 Silver Texture Silver PX521S343 Custom powder coat frame Note that Black is the standard color Texture Black PX622N365 Other options Up to 6 stops panoramic car ceiling balcony attachment Specification Specification Data ...

Страница 8: ...or and the car door shall not exceed 5 127 mm Vuelift Residential Elevator design is with a maximum 1 25 32 mm running clearance 3 4 4 rule code 2016 and after The ASME A17 1 2016 CSA B44 16 Safety Code for Elevators and Escalators 2016 AND AFTER mandates the following maximum hoistway door clearances see drawing on next page Clearancebetweenthe hoistway door and the hoistway edge ofthelandingsill...

Страница 9: ...hting disconnect 120V 15 Amp fused disconnect or circuit breaker Siemens Main disconnect 230V single phase disconnect model HF221N 240V 30 Amp with Interlock Kit HA 161234 Aux Contacts normally opened normally closed In addition two each 250V 20 Amp RK5 fuses Lighting disconnect 120V 15 Amp fused disconnect or circuit breaker G E Main disconnect 230V single phase disconnect model TH3221 240V 30 Am...

Страница 10: ...e installed in compliance with electrical code and are to be provided prior to installation of the unit Roughed in power to the lift must be provided to the head assembly location prior to installation of the unit Telephone If a telephone circuit is required the jack is to be provided and installed by others This circuit shall be brought to a location next to the controller and be available to con...

Страница 11: ...disconnects This can be the common house line in most jurisdictions Please check with your local installer or building contractor for code requirements Floor Built for Load Smooth level surface for installing the elevator with floor load bearing capacity for the elevator plus rated load An exact specification can be provided by contacting Savaria Floor and Pit Cutouts Complete If a pit is to be us...

Страница 12: ...ately reinforced Where necessary the building construction shall be reinforced to provide adequate support for the columns guide rails Shipping weight is estimated actual including crating materials etc Floor load figures include elevator structure weight when loaded with full test capacity Floor load figures shown here are actual loads your building engineer must add a proper factor of safety to ...

Страница 13: ...2018 Vuelift Planning Guide Drawings Round Plan view Pit bottom floor thru floor view Balcony detail Thru floor detail Elevation view Provisions by others Pit cutout detail Wheelchair plan view Controller box and UPS dimensions ...

Страница 14: ...14 Vuelift Planning Guide Part No 001123 16 m05 2018 Figure 1 Plan view round ...

Страница 15: ...15 Part No 001123 16 m05 2018 Vuelift Planning Guide Figure 2 Pit bottom floor thru floor view round ...

Страница 16: ...16 Vuelift Planning Guide Part No 001123 16 m05 2018 Figure 3 Balcony detail round ...

Страница 17: ...17 Part No 001123 16 m05 2018 Vuelift Planning Guide Figure 4 Thru floor detail round ...

Страница 18: ...18 Vuelift Planning Guide Part No 001123 16 m05 2018 Figure 5 Elevation view round ...

Страница 19: ...19 Part No 001123 16 m05 2018 Vuelift Planning Guide Figure 6 Provisions by others round ...

Страница 20: ...20 Vuelift Planning Guide Part No 001123 16 m05 2018 Figure 7 Pit cutout detail round ...

Страница 21: ...05 2018 Vuelift Planning Guide Figure 8 Wheelchair plan view round Notes No footrest used on wheelchair Size may vary Please review with your local dealer the availability of a true size template to review if chair will fit ...

Страница 22: ...Planning Guide Part No 001123 16 m05 2018 Figure 9 Controller box and UPS dimensions NOTE A remote controller cannot be more than 50 feet 15 24 meters away from the top of the unit in order for the cable to reach ...

Страница 23: ...23 Part No 001123 16 m05 2018 Vuelift Planning Guide Chapter 2 Octagonal Elevator Acrylic or Silica Glass ...

Страница 24: ...acrylic only 76 5 in 1 94 m Cab weight acrylic 500 lb 250 kg Cab weight silica glass 1000 lb 455 kg Cab floor area 12 83 sq ft 1 19 sq m Footprint 48 x 48 1 2 m x 1 2 m Power supply 30A 230 V single phase 50 60 Hz Cab lighting 15A 115V single phase 50 60 Hz Suspension Type Galvanized aircraft cable 2 x 3 8 diameter Construction IWRC 7 x 19 RHRL Nominal strength 14 400 lb 6 545 kg Weight of ropes 0...

Страница 25: ...ck up for cab lighting and lowering Options Optional configurations Type 1 2 3 Optional cab wall and hoistway Acrylic or low iron silica glass Optional colors White Texture White PX521W859 Silver Texture Silver PX521S343 Custom powder coat frame Note that Black is the standard color Texture Black PX622N365 Other options Up to 6 stops panoramic car ceiling balcony attachment Specification Specifica...

Страница 26: ... door and the car door shall not exceed 5 127 mm Vuelift Residential Elevator design is with a maximum 1 25 32 mm running clearance 3 4 4 rule code 2016 and after The ASME A17 1 2016 CSA B44 16 Safety Code for Elevators and Escalators 2016 AND AFTER mandates the following maximum hoistway door clearances see drawing on next page Clearancebetweenthe hoistway door and the hoistway edge ofthelandings...

Страница 27: ...ighting disconnect 120V 15 Amp fused disconnect or circuit breaker Siemens Main disconnect 230V single phase disconnect model HF221N 240V 30 Amp with Interlock Kit HA 161234 Aux Contacts normally opened normally closed In addition two each 250V 20 Amp RK5 fuses Lighting disconnect 120V 15 Amp fused disconnect or circuit breaker G E Main disconnect 230V single phase disconnect model TH3221 240V 30 ...

Страница 28: ... be installed in compliance with electrical code and are to be provided prior to installation of the unit Roughed in power to the lift must be provided to the head assembly location prior to installation of the unit Telephone If a telephone circuit is required the jack is to be provided and installed by others This circuit shall be brought to a location next to the controller and be available to c...

Страница 29: ...ctions Please check with your local installer or building contractor for code requirements Floor Built for Load Smooth level surface for installing the elevator with floor load bearing capacity for the elevator plus rated load An exact specification can be provided by contacting Savaria Floor and Pit Cutouts Complete If a pit is to be used a smooth level surface of at least 4 must be provided For ...

Страница 30: ... adequately reinforced Where necessary the building construction shall be reinforced to provide adequate support for the columns guide rails Shipping weight is estimated actual including crating materials etc Floor load figures include elevator structure weight when loaded with full test capacity Floor load figures shown here are actual loads your building engineer must add a proper factor of safe...

Страница 31: ...l loads your building engineer must add a proper factor of safety to the floor design Many jurisdictions require floor designs to include at least a safety factor of 2 0 doubling the loads shownhere To reiterate these figures DO NOT include your factor of safety for floor loads Engineer your floor to include add an appropriate safety factor and comply with local building codes Lower Floor Dead Loa...

Страница 32: ...lcony details Thru floor details Elevation view Provisions by others acrylic models Pit cutout thru floor cutout TYPE 2 Octagonal Glass Plan view Pit bottom floor thru floor view Balcony details Elevation view Provisions by others glass models Pit cutout thru floor cutout Wheelchair plan view octagonal Controller box and UPS ...

Страница 33: ...33 Part No 001123 16 m05 2018 Vuelift Planning Guide Figure 10 Plan view octagonal type 1 ...

Страница 34: ...34 Vuelift Planning Guide Part No 001123 16 m05 2018 Figure 11 Pit bottom floor thru floor view octagonal type 1 ...

Страница 35: ...35 Part No 001123 16 m05 2018 Vuelift Planning Guide Figure 12 Balcony detail octagonal type 1 ...

Страница 36: ...36 Vuelift Planning Guide Part No 001123 16 m05 2018 Figure 13 Thru floor detail octagonal type 1 ...

Страница 37: ...37 Part No 001123 16 m05 2018 Vuelift Planning Guide Figure 14 Elevation view octagonal type 1 ...

Страница 38: ...38 Vuelift Planning Guide Part No 001123 16 m05 2018 Figure 15 Provisions by others octagonal acrylic models type 1 ...

Страница 39: ...39 Part No 001123 16 m05 2018 Vuelift Planning Guide Figure 16 Pit cutout thru floor cutout octagonal type 1 ...

Страница 40: ...40 Vuelift Planning Guide Part No 001123 16 m05 2018 Figure 17 Plan view octagonal glass type 2 ...

Страница 41: ...41 Part No 001123 16 m05 2018 Vuelift Planning Guide Figure 18 Pit bottom floor thru floor view octagonal glass type 2 ...

Страница 42: ...42 Vuelift Planning Guide Part No 001123 16 m05 2018 Figure 19 Balcony detail octagonal glass type 2 ...

Страница 43: ...43 Part No 001123 16 m05 2018 Vuelift Planning Guide Figure 20 Elevation view octagonal glass type 2 ...

Страница 44: ...44 Vuelift Planning Guide Part No 001123 16 m05 2018 Figure 21 Provisions by others octagonal glass type 2 ...

Страница 45: ...45 Part No 001123 16 m05 2018 Vuelift Planning Guide Figure 22 Pit cutout thru floor cutout octagonal glass type 2 ...

Страница 46: ...e Part No 001123 16 m05 2018 Figure 23 Wheelchair plan view octagonal Notes No footrest used on wheelchair Size may vary Please review with your local dealer the availability of a true size template to review if chair will fit ...

Страница 47: ...001123 16 m05 2018 Vuelift Planning Guide Figure 24 Controller box and UPS dimensions NOTE A remote controller cannot be more than 50 feet 15 24 meters away from the top of the unit in order for the cable to reach ...

Страница 48: ...ential Elevator PLANNING GUIDE Part No 001123 Copyright 2018 Savaria Concord Lifts Inc www savaria com Sales 2 Walker Drive Brampton Ontario L6T 5E1 Canada Tel 905 791 5555 Fax 905 791 2222 Toll Free 1 800 661 5112 ...