14
Telecab Owner’s Manual
Part No. 000627, 09-m03-2010
5. MAINTENANCE
The owner can perform the 2-month inspections, but the 6-month inspections
must
be
performed by a Qualified Technician. Contact your Authorized Dealer
.
Maintenance Schedule
Verification by owner
Frequency
Verify general operation of the Telecab
Every 2 months
Verify operation of the safety devices:
• Underpan sensors (safety switches)
• Floor plug sensors (safety switches)
• Door contact
• Door lock
• Emergency stop
Every 2 months
Verification by technician
Frequency
Verify operation of the emergency lowering system
Every 6 months
Verify operation of the safety brake
Every 6 months
Check the safety components:
• Chains
• Chain connecting links
• Chain pulleys and shafts
• Parts holding the chains on the roller supports
• Chain tensioners on the rail (ensure they are tight)
• Cylinder head (cotter pins, cracks, welds)
• Hydraulic system (check for leaks)
• Fastening devices (check for looseness)
• Up relays – verify that one of the two up relays is not
stuck in the activated position. Use a multimeter to verify
that every normally-open contact is open when the
relays are not being activated.
Every 6 months
Check the rollers
Every 6 months
Check for oil leaks
Every 6 months
Check the fluid level
Every 6 months
Check the battery fluid level (optional system)
Every 6 months