background image

       3

Part No. 000849, 29-m05-2014

Pro-lock maintenance

2

With proper adjustment, the contacts should be as shown in Figure 2 below.

Figure 2

Critical Measurements

3

If adjustment cannot be made to meet the measurements shown above, follow these steps (see Figure 3):
a. Inspect the screws (A) holding the contact mounts and ensure they are tight.
b. Inspect the mounts (B) and ensure they are not damaged.
c. Inspect the nuts (C) on the contacts and ensure they have flat and lock washers installed, and that they are tight.
d. Older models may have a clip (instead of nuts) and have soldered wires. Ensure they are tight and the solder 

connections are in good repair.

e. Replace the lock if any of these items cannot be corrected without making modification to the lock.

Figure 3

Inspect if measurements are not met

Lock Plunger Not Depressed

Lock Plunger Depressed

Approx. 3mm (using a pencil)

4mm - 5mm

C

B

A

TSSA web posted and current as of July 2014. Note: May be 

subject to revision 

by Savaria 

Отзывы: