Wiring and Connections

HDBaseT Link Wiring

 

IMPORTANT! Precautions and Recommendations

The HDBaseT connections on the SmartLink Matrix are 5Play 
compliant and feature Power over HDBaseT (PoH) which can 
supply power to compatible HDBaseT receivers.
Read the 

Using Power over HDBaseT (PoH)

 section before 

making any connections to avoid damaging connected devices.

HDBaseT di

ers from Ethernet and PoH has di

erent 

specifications than PoE.  The HDBaseT connections should never 
be connected to a network router or switch. Doing so may cause 
damage to connected equipment.

While HDBaseT transmission technology is much less susceptible 
to electromagnetic interference (EMI) than other transmission 
technologies, Savant recommends that shielded Cat 5e/6/7 
cable and shielded RJ-45 connectors are used for maximum 
signal reliability.

HDBaseT Pinout (EIA 568B Standard)

Using Power over HDBaseT (PoH)

Power over HDBaseT allows for 5Play compliant HDBaseT receivers 
to receive power on the same cable as the audio, video, IR, RS-232, 
and Ethernet.  This eliminates the need for a power supply 
connected to the receiver.   When non 5Play compliant receivers are 
used, PoH must be turned OFF on the transmitter’s link port before 
making any connections.

DIP Switch Settings

Power Over HDBaseT Enabled

Power Over HDBaseT Disabled

RS-232 Wiring

The RS-232 ports follow the Savant standard with pin 5 as RXD 
(receive) and pin 6 as TXD (transmit).  The diagram below shows 
the wiring for the HTX-SLN501 side of the cable, the wiring on the 
opposite side may vary based on the device’s pin configuration.

Note

: Pins 5 and 6 must be switched if connecting a Savant Controller 

to the HTX-SLN501.

RJ-45 to DB9 Adapters

Savant o

ers RJ-45 to DB9 adapters in a variety of configurations 

that can be used for RS-232/422/485 control. 
Refer to the 

RS-232 Conversion to DB9 and RS-422/485 Pinout 

Application Note

 located on the 

Savant Customer Community

 for 

more information on RJ-45 to DB9 adapters.

 

IMPORTANT! 

If you are using RJ-45 to DB9 adapters not supplied by Savant:

Ensure that any wires required for communication/control are 
terminated within the adapter.

Ensure that all wires NOT required for communication/control 
are NOT terminated in the connector.

Ensure that the unused wires in the connector are cut to prevent 
them from shorting out, as they are still terminated in the RJ-45 
connector on the controller side.

IR Wiring

IR connections are made using the 4-pin Screw Down Plug-in 
Connector supplied with receiver.  The wire slips into the hole and 
locks with the screw located at the top of the connector.

 

IMPORTANT!

 

IR Wiring Precautions

Ensure that all IR emitters are within 15 feet (4.6 meters) from 
the controllers location.

Use of 3

rd

 party flashing IR emitters with Talk Back is not 

recommended. These types of emitters can draw voltage away 
from the IR signal that can degrade IR performance.

 

Tip:

When installing wire in screw down terminals, strip a 1/4 inch of 
insulation from the each wire and twist the strands together.  This 
will allow for the exposed wire to be inserted into the terminal up 
to the insulation, eliminating stray strands that may cause 
shorting.

Additional Information

Refer to the following documents located on the 

Savant  Customer 

Community

 for additional information.

SmartLink HDMI Matrix Switch Deployment Guide

HTX-SLN501-00  |  009-1102-07  |  160222

HTX-SLN501-00  |  009-1102-07  |  160222

45 Perseverance Way, Hyannis, MA 02601

Copyright © 2016 Savant Systems, LLC

2 of 2

Savant.com

  |  508.683.2500

Отзывы: