Wiring and Connections
RS-232 Wiring
The RS-232 ports follow the Savant standard with pin 5 as RXD
(receive) and pin 6 as TXD (transmit). The diagram below shows
the wiring for the HRX-SLN501 side of the cable, the wiring on the
opposite side may vary based on the devices pin configuration.
RJ-45 to DB9 Adapters
Savant o
ff
ers RJ-45 to DB9 adapters in a variety of configurations
that can be used for RS-232/422/485 control.
Refer to the
RS-232 Conversion to DB9 and RS-422/485 Pinout
Application Note
located on the
Savant Community
for more
information on RJ-45 to DB9 adapters.
IMPORTANT!
If you are using RJ-45 to DB9 adapters not supplied by Savant:
•
Ensure that any wires required for communication/control are
terminated within the adapter.
•
Ensure that all wires NOT required for communication/control
are NOT terminated in the connector.
•
Ensure that the unused wires in the connector are cut to prevent
them shorting out, as they are still terminated in the RJ-45
connector on the controller side.
IR Wiring
IR connections are made using 4-pin Screw Down Plug-in
Connector supplied with receiver. The wire slips into the hole and
locks with the screw located at the top of the connector.
IMPORTANT!
IR Wiring Precautions
•
Ensure that all IR emitters are within 15 feet (4.6 meters) from
the controllers location.
•
Use of 3
rd
party flashing IR emitters with Talk Back is not
recommended. These types of emitters can draw voltage away
from the IR signal that can degrade IR performance.
Additional Information
Refer to the following documents located on the
Savant
Community
for additional information.
•
SmartLink Matrix Blueprint Deployment Guide
HRX-SLN501-00 | 009-1025-04 | 150330