Savant HCX-4KHDR40 Скачать руководство пользователя страница 2

HCX-4KHDR40  | 009-1673-02 

Copyright 2020 Savant Systems, LLC  |  200406

2     of     2

45 Perseverance Way, Hyannis, MA 02601 

Savant.com  |  508.683.2500

Installation

An HDBaseT extender can be placed on a standard 1U rack shelf, or 

can be installed using the included mounting brackets. To install the 

mounting brackets, follow the steps below.

1.  Remove the two case screws on the side of the device 

(Shown in the image below).

2.  Align the bracket using the top holes. 

NOTE

: This will leave an air gap behind the device.

3.  Replace the case screws attaching the bracket.

HDBaseT Cable Information

Category 6 or greater twisted pair cable with RJ-45 connectors 

between the transmitter and the receiver is recommended.  

TIA/EIA-568B straight-through wiring connections must be used.

Transport Distance (4K)

Cat6 

 

 

115 ft (35 m)

Cat6a/7   

 

131 ft (40 m)

Transport Distance (1080P)

Cat6 

 

 

197 ft (60 m)

Cat6a/7   

 

230 ft (70 m)

RJ-45 Connector

(Gold pins facing up)

TIA/EIA-568B

1

2

IR Wiring

IR Control is pass-through only.

IR Emitter

Connect to 3.5 mm IR Out to control a IR device. 

3

2

1

Pin  1

IR - (Black)

Pin  2

IR + (Red)

Pin  3

Not Used 

IR Connector Cable

Connect to 3.5 mm IR In to pass-through IR control from a Savant 

Controller. 

IR Receiver

Connect to 3.5 mm IR In to pass-through IR control. Not 

commonly used in a Savant Deployment.

RS-232 Wiring

RS-232 control signal pass-through only. 

Serial control connections are made using 

a 3-pin Control Connector supplied with 

the device. The wire slips into the hole 

and locks with a screw located at the top 

of the connector.

IMPORTANT NOTE!

 Use of a crossover 

cable between the controller and the Transmitter is required.

Pin  1

Ground

Pin 2

2

Transmit

Pin 3

Receive 

1

3

Отзывы: