2

4.0

 

 Operation Guide  

1.

Install batteries

Slide off the cover case of the battery room, and put into two AA alkaline batteries. Then slide

 

the cover case back. The power of two AA alkaline batteries could last for two years.

2.

Connecting fitting

The thread specification of the DigiFlow 8300T-

66

 is 

3/4

” 

NPT

 male.

3.

Programming monitoring capacity

Press “PROG” button, the “ProG” blinks on the LCD. Then press “RESET” to choose the right

 

value to save from the right digit. Once the value is chosen, press “PROG” button to save the

 

value and goes to the next digit. Repeat the above procedure to program the values for five

 

digits from right to left. The maximum monitoring capacity for the DigiFlow 8300T-

66

 is

 

99

,

999

 

Gallon

s

. If there is no input for one minute

 

during the programming procedure, the

 

programming procedure will be terminated and goes

 

back to the original status.

4.

Operating

The DigiFlow 8300T-

66

 automatically turns on and displays the remaining capacity when

 

there is water flowing through the sensor. And it automatically turns off in 10 seconds when

 

there is no water flowing.

5.

End of capacity alert

The DigiFlow 8300T-

66

 generates an audible alert and the digits on the LCD blinks when its

 

remaining capacity reaches zero or minus.

6.

Resetting

Press the “RESET” button for three seconds, the “rESEt” on the LCD blinks twice, and the

 

remaining capacity is reset to the original programming value.

7.

Low battery power alert

When the battery power is low, the DigiFlow 8300T-

66

 generates an audible alert and the

 

empty battery symbol on the right-up corner of the LCD blinks. The alert status will be

 

released when the batteries are replaced by new batteries. The data of the last status will be

 

memorized and stored back. 