3
Materials : Sensor Body : Acetal Copolymer, TICONA M90
Turbine : Acetal Copolymer, TICONA M90
Stick of Turbine : #304 Stainless Steel
O-Ring : EPDM Rubber
Housing : ABS resin
5.0
Operation Guide
5.1 Install Batteries
Slide off the cover case of the battery room, and put into 2 AAA batteries. Then slide the cover case
back.
5.2 Connecting Fitting
The specification of the DigiFlow 6700M connectors is 3/8” MNPT female. You could use any 3/8”
MNPT male connectors.
5.3 Operating
The DigiFlow 6700M will automatically turn on when there is water flowing through the sensor. It
will automatically turn off in 10 seconds when there is no water flowing.
5.4 Display and Mode Selection :
Press the “DISPLAY” button will turn on the LCD of the DigiFlow 6700M. Pressing the
“DISPLAY” button again could choose to display accumulated flowing volume (flow totalization)
or real-time flow rate.
5.5 Low Battery Power Alert
When the battery power lower than normal working level, the buzzer will beep twice to notice and
the battery symbol on the screen will blink to notice user to change the battery. Once the batteries
are replaced, the alert will be released. The data will be kept in memory and stored back when user
replace the batteries.