Mounting
Can be either surface mounted using a pair of mounting brackets (SMB-8000-XX) or
flush mounted between two 16 inch on center studs. For more information on
mounting, refer to the deployment guides for the CLI-8000 (009-1073-XX) or
CLI-8000A (009-1154-XX).
Option 1: Mount between studs (Flush Mount)
1. Locate two adjacent studs that are 16 inch on center. If there is drywall, cut to the
dimensions below.
2. Slide between studs. On left and right side there are three mounting holes. Screw
to inside of studs through these holes.
Option 2: Optional Brackets (Surface Mount)
1. Screw the mounting brackets to the right and left side of the CLI-8000 using (4)
10-32 x
⅜
inch FH machine screws.
2. The mounting brackets are 16 inch on center so the TPU can be screwed to two
adjacent studs. Locate two adjacent studs that are 16 inch on center.
3. Screw the TPU to the wall through the drywall and into the studs using
appropriate self tapping drywall screws or equivalent.
Connect Input Power
1. Remove the access panel by removing the screw holding down the access panel.
2. Locate the
½
inch electrical knockout just below access panel. Remove knockout
and install electrical clamp.
3. Connect the 24V AC from transformer to the two position screw terminal block
under the power input panel.
Note:
Use a minimum of 18 AWG wire when connecting the input power.
Copyright © 2014 Savant Systems, LLC. SAVANT and RacePoint Blueprint are trademarks of Savant Systems, LLC.
All brand names, product names and trademarks are the property of their respective owners.
Savant Systems, LLC reserves the right to change product specifications without notice.
HVAC Relay Wiring
The figure below is the top view of the eleven position screw terminal connector that
is plugged into each relay bank. Ensure all power from both the HVAC and
CLI-8000/8000A systems have been removed before making connections.
1. Remove connector from its mate on front panel.
2. Insert correct wire into front of plug using information in the table below.
3. Tighten screw so that wires are clamped inside the connector.
4. Reinsert into the proper relay bank.
5. Wire other side to HVAC system.
Relay
Description
RH - Red
Wired to hot side of transformer on heating equipment.
RC - Red
Wired to hot side of transformer on cooling equipment.
W1 - White
Wired to stage 1 heat terminal (W1) on HVAC system.
W2 - Black
Wired to stage 2 heat terminal (W2) on HVAC system.
Y1 - Yellow
Wired to stage 1 cooling terminal (Y1) on HVAC system.
Y2 - Blue
Wired to stage 2 cooling terminal (Y2) on HVAC system.
O - Orange
Wired to (O) terminal on Heat Pump System. Reversing Valve
connection.
G - Green
Wired to fan terminal (G) on HVAC system.
C NO NC
C = Common Terminal
NO = Normally Open, Connects with C when the Relay is ON.
NC = Normally Closed, Connects with C when the Relay is OFF.
NOTE:
Since there is no standard for wire colors in HVAC, the colors shown in table
are typical. Refer to manufacturers documentation to HVAC system before wiring.
NOTE:
If required, RH and RC can be jumped together.
Remote Sensor Connections
Wiring diagram connecting the CLI-THFM1 sensor to the CLI-8000/8000A. Up to two
CLI-THFM1 sensors per zone.
In addition to the CLI-THFM1 Smart Sensor described above, other sensors are
available. For information on the these sensors, refer to the Quick Reference Guides
(QRG’s) for each sensor.
Additional Documentation
Once the CLI-8000/8000A TPU has been installed, the next few steps will need to be
followed to get the system up and running:
• Wire CLI-8000/8000A to additional HVAC system(s).
• Wire additional remote sensors to the CLI-8000/8000A
• Power on the CLI-8000/8000A
• Update the firmware to latest version (If Required)
• Configure the system to your specific application.
Documentation covering all the above procedures is available in the Savant
Portal
located at
dealers.savantsystems.com
Products > Savant Hardware > Climate Control
Savant
®
Centralized Climate Control Deployment guide (009-1073-XX, CLI-8000)
Savant
®
Centralized Climate Control Deployment guide (009-1154-XX, CLI-8000A)
Thermostat Processing Unit
(CLI-8000-00/8000A-00)
Quick Reference Guide
009-1090-01
CLI-8000-00
CLI-8000A-00
Savant
®
Centralized Climate Solution CLI-8000/8000A Quick Reference Guide
Savant
®
Centralized Climate Solution CLI-8000/8000A Quick Reference Guide
Savant
®
Centralized Climate Solution CLI-8000/8000A Quick Reference Guide
Savant
®
Centralized Climate Solution CLI-8000/8000A Quick Reference Guide
Savant
®
Centralized Climate Solution CLI-8000/8000A Quick Reference Guide
Savant
®
Centralized Climate Solution CLI-8000/8000A Quick Reference Guide
009-1090-01
31314
2
of
2