Savannah Heating TASMAN 5000 Скачать руководство пользователя страница 11

Page 11 of 18 

 

  

INSTALLATION & SAFETY NOTES  

Read all instructions before starting installation and follow them carefully during installation to ensure 
maximum  benefit  and  safety.   Failure  to  follow  these  instructions  will  void  your  warranty  and  may 
present a fire hazard.  See the warranty at the back of this manual for disclaimers regarding improper 
installation.   This  outdoor  fireplace  and  it s  components  are  tested  and  safe  when  installed  in 
accordance with this installation manual.    

UNPACKING  

Please check the appliance carefully for any damaged or missing components.  Report any problems 
to your dealer within 30 days of purchase.    

MINIMUM CLEARANCES   

The minimum clearance to combustibles for the sides and the top is 36  (914 mm).  

This outdoor fireplace is suitable for installation on a combustible surface.   

Clearances  are  in  accordance  with  local  installation  codes  and  the  requirements  of  the  gas 

supplier.

  

Pedestal Door Installation  

Fit  the  door  tabs  into  the  notches  on  each  side  of  the  pedestal  base  and  let  door  slide  down  into 
place.  Removal is the reverse.   

 

 

Tabs fit into slots

 

Lift door up and out.

 

Содержание TASMAN 5000

Страница 1: ...ch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier c...

Страница 2: ...nformation 10 Leak Testing 10 INSTALLATION Minimum Clearances 11 Pedestal Door Installation 11 Initial Firing Primary Air Adjustment 12 Altitude Adjustment 13 Field Assembled Parts 13 Lava Rock Log In...

Страница 3: ...ESSURE Minimum 7 0 w c 1 74 kPa Minimum 11 w c 2 74 kPa MAXIMUM GAS INLET SUPPLY PRESSURE Maximum 13 5 w c 3 4 kPa Maximum 13 5 w c 3 4 kPa AIR SHUTTER SETTING adjustable from fully closed to fully op...

Страница 4: ...Page 4 of 18 APPLIANCE DIMENSIONS TASMAN 5000 TASMAN 5000S...

Страница 5: ...al Fuel Gas Code ANSI Z233 1 or the current CAN CGA B149 1 Installation Codes In the state of Massachusetts this product can only be installed by a licensed plumber or a licensed gas fitter Failure to...

Страница 6: ...and to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result...

Страница 7: ...HI LO knob to control the flame height To adjust the flame height turn the adjustment knob Turning the knob in a clockwise direction sets the valve to the maximum setting turning the knob in the coun...

Страница 8: ...or to each use If the hose is damaged or there are signs of excessive abrasion or wear replace the hose See page 9 on how to gain access to hose assembly Use only the pressure regulator and hose assem...

Страница 9: ...Then you slide the tank into place there is a round hole which the base of the LP cylinder will fit into Then you would attach the regulator hose assembly leak test see page 11 and replace the pedest...

Страница 10: ...at are to be used with natural gas the appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of the gas system at test pressures...

Страница 11: ...e with this installation manual UNPACKING Please check the appliance carefully for any damaged or missing components Report any problems to your dealer within 30 days of purchase MINIMUM CLEARANCES Th...

Страница 12: ...ter to increase or decrease primary air see below and tighten the screw Increasing the primary air will cause the flame to appear more transparent and blue Decreasing the primary air will cause the fl...

Страница 13: ...ced 4 for each additional 1000 feet 305m above sea level For the USA de rate the unit from sea level according to the gas installation code FIELD ASSEMBLED PARTS Your outdoor fireplace comes fully ass...

Страница 14: ...Page 14 of 18 BURNER FLAME...

Страница 15: ...rials or use components other than factory supplied RECOMMENDED SERVICE 1 Visually check the burner flame occasionally Visually inspect height and color of flames see page 21 2 Have the appliance insp...

Страница 16: ...sure 1 Gas line shut off 1 Turn on shut off valves 2 Air in gas lines 2 Purge gas lines 3 Gas lines may not be connected 3 Connect all gas lines 4 Low pressure may be caused by bent line 4 Check for a...

Страница 17: ...h Inca provided that the purchase was made through an authorized Inca dealer and is subject to the following conditions and limitations This factory warranty is nontransferable and may not be extended...

Страница 18: ...defined as above and it shall not in any event extend to any incidental consequential or indirect damages This warranty defines the obligations and liability of Inca with respect to the Inca gas firep...

Отзывы: