Содержание SAUTER TC car

Страница 1: ...36 Balingen E Mail info sauter eu Tel 49 0 7433 9933 199 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction Manual Digital Coating Thickness Gauge SAUTER TC car Version 1 2 08 2017 GB TC_car BA e 1712 PROFESSIONAL MEASURING ...

Страница 2: ... are pleased with your high quality Thickness Gauge with its big functional range If you have any queries wishes or helpful suggestions do not hesitate to call our service number Summarize 1 Features 3 2 Specifications 3 3 Front panel description 4 4 Measuring Procedure 4 5 Adjustment 5 6 Battery replacement 6 7 Adjustment foils 6 8 Trouble shooting 6 9 Restore Factory Settings 6 ...

Страница 3: ...s e g steel iron nickel etc It is often used to measure the thickness of galvanizing layer lacquer layer porcelain enamel layer phosphide layer copper tile aluminium tile some alloy tile paper etc The N sensor measures the thickness of non magnetic coatings on non magnetic metals It is used on anodizing varnish paint enamel plastic coatings powder etc It can be applied on non magnetic materials li...

Страница 4: ...ils Base plate iron Base plate aluminium Optional accessories Cable software for RS 232C ATC 01 3 Front panel description 3 1 Sensor F and N inbuilt 3 2 Display 3 3 Zero key Power on Power off key 3 4 Battery compartment cover 3 5 Jack for RS 232C interface 4 Measuring Procedure a The Power on Power off key 3 3 has to be pressed to switch on the instru ment 0 appears on the display 3 2 The instrum...

Страница 5: ... key is released This lasts about 8 seconds The symbol on the display indicates the continuous mode To change back to single mode just press the Power key again for 8 seconds If has disappeared on the display you are back in single measurement mode 5 Adjustment a Zero adjustment Zero adjustment for Fe F and NFe NF should be carried out separately The iron base plate has to be used if Fe is shown o...

Страница 6: ...e the coatings are 9 Restore Factory Settings a It is recommended to restore factory settings in following cases The instrument does not measure any more Measurement accuracy is degraded caused by drastic environmental changes b How to restore To restore factory settings includes both Fe setting and NFe setting Please note which symbol is shown on the display You can restore only one of them or bo...