Instruction manual digital force 
gauge

 

 

 

 

SAUTER FC 

Version 2.0 
01/2020 
GB  
 

 
 
 

 

 

 PROFESSIONAL MEASURING 

Содержание FC

Страница 1: ...GmbH Ziegelei 1 D 72336 Balingen e mail info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction manual digital force gauge SAUTER FC Version 2 0 01 2020 GB PROFESSIONAL MEASURING ...

Страница 2: ...o contact us if you have any questions requests or suggestions Table of contents 1 Introduction 3 2 Scope of delivery 3 3 Technical data 4 3 1 Technical data FC with internal loadcell up to 1kN 4 4 Display indication 5 5 Control buttons 6 6 Menu items 7 6 1 Language 7 6 2 Display modes 7 6 3 Storing measured values 7 6 4 Delete all records 7 6 5 Browse Menu 8 6 6 Print 9 6 7 System settings 9 6 8 ...

Страница 3: ...vident please notify SAUTER GmbH immediately The FC can measure tensile and compressive forces very accurately and it is easy to operate It can be held in the hand for measurements or mounted on a suitable test stand SAUTER offers optional software and accessories to make the measuring instrument more versatile in use Please ask SAUTER or the SAUTER supplier or visit our website www sauter eu 2 Sc...

Страница 4: ...asuring device FC 10 FC 50 FC 100 FC 500 FC 1K Capacity 10N 50N 100N 500N 1000N Measurement uncertainty 0 3 of Max measuring range Work temperature 15 C to 35 C Relative air humidity 15 to 80 Humidity Weight without accessories Approx 500g Dimensions Display unit LxWxH 140x71x36mm Thread M6 ...

Страница 5: ...ween the lower and upper limit and is OK the value is between the lower limit value and the value of 75 of the lower limit value i e the value falls below the lower limit value the value exceeds the upper limit value 4 Measuring units the selected unit is displayed N kgf ozf or lbf optional 5 System Clock 6 Data transmission symbol 7 Data memory icon 8 Analogue load bar display 9 Current measured ...

Страница 6: ...ESC button in the menu you can return to the previous page ZERO zeroing Zeroing the display Arrow up in the menu ENTER Opening the menu Confirm the selection in the menu Mode mode change Selecting the measuring mode Arrow key down in the menu ON OFF On Off button press button for approx 1 s ...

Страница 7: ... equipped with the function for storing measured values The stored data can be searched or printed out During the measurement press the key to save the respective value The display will show the data storage symbol The stored data is displayed In Track mode and Preset mode the current force value is measured and in Peak mode the maximum value 6 4 Delete all records To empty the memory all data can...

Страница 8: ...on window appears on the display In this window you can choose between the Delete or Print option If the Delete option is selected a dialog box with a corresponding security prompt is displayed To exit the menu press the key If the percentage drop is between 5 10 please contact the supplier to have the loadcell replaced These values are given as a guide only The actual need for calibration replace...

Страница 9: ...en the function Selected or All If the Selected option is selected the pressure range must be determined If you choose the All option a dialog box appears with a confirmation prompt 6 7 System settings In the System menu settings for the display automatic switch off function backlight key tone etc can be selected Fig 3 8 ...

Страница 10: ...ultifunctional port The PIN assignment is shown in the table Pin Description 1 TX RS232 2 RX RS232 3 GND RS232 4 Default value output B 5 6 Default value output C general 7 Default value output A 8 6 9 1 RS 232 The RS232 interface is only used to connect a mini printer to print out the data received RS 232 specification Hardware flow control none Word length 8 bits Stop bit 1 bit Parity none Data ...

Страница 11: ...t value circuit Pins 6 and 7 are switched on after the overload alarm is triggered In setting mode pins 6 and 7 are switched on after the upper limit value has been exceeded and pins 4 to 6 after the lower limit value has been fallen below Max permissible voltage for pins 7 to 6 and 4 to 6 the voltage must be below 35V and for pins 6 to 7 pins 6 to 4 below 6V ...

Страница 12: ...could be damaged and the measuring accuracy will decrease in any case Inappropriate use Do not use the measuring instrument for medical weighing If small quantities of the material to be measured are removed or added incorrect measurement results may be displayed due to the stability compensation in the measuring instrument Example Slow flow of liquids out of a container suspended from the measuri...

Страница 13: ...ty The warranty is void if Non compliance with our guidelines of the operating instructions Use outside the described field of application Modifying or opening the device mechanical damage and damage caused by agents such as liquids or liquids have been caused improper assembly or electrical installation Overloading the measuring cell Test equipment monitoring As part of quality assurance the metr...

Страница 14: ...essing the key 3 Call up the calibration menu 4 Load with test weight The current measured value now equals the test weight load Wait until the measured value stabilizes before reading the measured value 5 Use the and keys to enter the test weight 6 Press the key to initiate a new calibration procedure The calibration process can be interrupted by pressing the key If the calibration procedure is c...

Страница 15: ...FC BA e 2020 15 9 Technical drawings 4 M3x8 ...