WATER HEATER INSTALLATION

LOCATION

When determining the siting of the water heater,
make sure you keep an approx. distance of 50 mm
between the sides of the appliance to ensure total
accessibility for servicing.
The jig will enable you to determine the position of
the flue system hole at the top outlet. All informa-
tion regarding the installation of the flue system is
provided in the flue system package.
If the water-heater is not fitted straight away, the
water and gas fittings must be protected from
contaminents E.G. plaster, paint.

PIPE FITTINGS : Gas

 Manual gas cock 3/4" F - 1/2" M

Cold water inlet

 : stop cock 3/4" F - 1/2 " M with

angled tail

DHW outlet

 : 3/4" F - 1/2 " M angled tail

This appliance must be installed in accordance with
the current issue of :

The gas safety (installation and use) regulations

The building regulations

The local water company byelaws

The building standards regulations (Scotland)

The health and safety at work act.

The gas safety (installation and use) regulations : it is
the law that all gas appliances are installed by
competent persons in accordance with the above
regulations. Failure to install appliances correctly
could lead to prosecution. It is in your own interest,
and that of safety, to ensure the law is complied
with.

TECHNICAL DATA

Refer to the data badge for exact type of appliance
and the gases it is suitable for.

Variable output of

8,7 kW (29665 Btu/h)

to 22,7 kW (77403 Btu/h)

Efficiency

78,4 %

Minimum flow rate, hot water temperature to :
maxi. position

2,7 l/min (0,60 g/min)

mini. position

4,2 l/min (0,92 g/min)

Maximum flow rate (by flow limiter)

3 l/min (2,86 g/min)

Specific flow rate (

t 30 

°

C)

11 l/min (2,42 g/min)

Minimum water pressure

[

pw

] 0,3 bar (4,50 Ib/in

2

)

Maximum water pressure

*

[

pw

] 10 bar (150 Ib/in

2

)

Max hot water temperature

60 

°

C

Venting of flue gases via flue system

Ø 60 mm

Incoming fresh air via flue system

Ø 100 mm

Supply voltage

230 V

Current

0,31 A

Power

55 W

Electrical protection

IP 44

* These maximum water pressure values take into account
the dilation of the water.

Only a qualified technician is authorized to intervene on
sealed mechanisms.

Gas Category :

 

II

2H3+

.

Ø buner injector

1,20 mm

Appliance Inlet pressure

20 mbar

Max. gas flow rate output

2,75 m

3

/h

Min. gas flow rate

1,13 m

3

/h

Natural (G 20) 

(ref. 15

°

C and 1013 mbar)

Ø buner injector

0,80 mm

Appliance Inlet pressure

28 - 30 mbar

Max. gas flow rate output

2,04 kg/h

Min. gas flow rate

0,83 kg/h

Butane (G 30)

Ø buner injector

0,80 mm

Appliance Inlet pressure

37mbar

Max. gas flow rate output

2,02 m

3

/h

Min. gas flow rate

0,82 m

3

/h

Propane (G 31)

Car 019

100 100

141

141

445,2

316,4

61,6

17

17

19,5

EF

EC

GAZ

86
103

AC

GAS

AF

134

50

mini

245 mini

100

100

141

141

445,2

3

16,4

61,6

17

17

19,5

EF

EC

GAZ

100 mm

100 mm

316,4 mm

3%

Ø 105

Ins 052

Содержание OPALIA X13

Страница 1: ...1 THESE ARE CAT II2H3 APPLIANCES 01773 828100 IN WARRANTY TECHNICAL HELPLINE 01773 828400 O P A L I A ...

Страница 2: ...ver the rate at which water is drawn there will be instantaneous hot water at a very nearly constant temperature within the maximum capacity of the appliance The ignition system on this water heater with no permanent pilot has been designed to achieve maximum energy saving INSTALLATION AND USER INSTRUCTIONS UK OPALIA X13 Mandatory warning notice for CEE countries WARNING this appliance was designe...

Страница 3: ...us size spouts are available Please contact your supplier HEATER SCHEMATIC 1 Air pressure switch 2 Fan 3 Overheat cut out system 4 Ignition electrode 5 Flame sense electrode 6 Gas valve 7 Temperature sensor 8 Flow sensor 9 Control PCB 10 Temperature adjustment 11 Heat exchanger 1 3 5 6 7 2 4 11 8 9 10 1 mini Incoming air Outlet of combustion products Shy 112a slope of 35 mm per metre min ...

Страница 4: ...Refer to the data badge for exact type of appliance and the gases it is suitable for Variable output of 8 7 kW 29665 Btu h to 22 7 kW 77403 Btu h Efficiency 78 4 Minimum flow rate hot water temperature to maxi position 2 7 l min 0 60 g min mini position 4 2 l min 0 92 g min Maximum flow rate by flow limiter 3 l min 2 86 g min Specific flow rate t 30 C 11 l min 2 42 g min Minimum water pressure pw ...

Страница 5: ... exceeds 7 5 m include adapter TWIN PIPE FLUE 2 x Ø 80 mm Important remove the flue restrictor ring when L exceeds 1 m Important remove the flue restrictor ring when L exceeds 4 m Maximum flue index 60 Pa This value is reached when L1 L2 exceeds 11 m includes elbows and terminal Important remove the flue restrictor ring when L1 L2 exceeds 8 m The flue must be fitted with a minimum slope of 35 mm p...

Страница 6: ...supply Ensure that the live and neutral are connected correctly To comply with current standards this connector must be made through a double pole switch with a contact separation of no less than 3 mm FLUE LOCATION Minimum dimensions in mm for the positioning of flue terminals N C D M A B E F G I H L Ven 060b A Under a window 600 B Under an air vent 600 C Under a gutter 300 D Under a balcony 300 E...

Страница 7: ...function or an abnormality gives rise to the disconnection of the appliance and the safety indicator 4 lights To restart the water heater press the RESET button 3 SAFETY DEVICES Air flow safety device air pressure switch In the event of even partial blockage of the flue for whatever reason resulting in a reduced air flow the water heater s built in safety device comes into operation the burner is ...

Страница 8: ... gas supply Shut off water supply open all hot water taps If the kind of gas supplying the appliance is changed certain parts of the burner and pilot need to be modified These modifications and the new adjustments they involve must only be carried out by a qualified engineer Toensurethecontinuedefficientandsafeoperation of the water heater it is recommended that it is checked and serviced annually...

Страница 9: ...heck electrode lead change if necessary check flame sense lead change if necessary change ignition PCB change main PCB no electrical supply no gas flow gas valve reversed live and neutral flue system ignition system the water heater will not run but the safety indicator light is not lit the water heater will not run safety disconnection the spark train does not light the burner safety disconnectio...

Страница 10: ...ve ignition module water flow sensor Diag B connections to main PCB behind control housing Diag C controls gas and water connections Diag D fan connections Diag E gas valve modulator connections Diag F temperature sensor connections Diag G air pressure switch connections Diag H overheat thermostat connections Diag I flow sensor Diag J ignition and flame sense electrodes ...

Страница 11: ... improve the quality of its appliances Saunier Duval reserves the right to modify the latter without prior notice The technical information contained in our documents are given for guidance only and are without liability ...

Страница 12: ...12 106201 E 07 99 ...

Отзывы: