Saunacore CTY-WN16 Скачать руководство пользователя страница 6

 

Cross Section View of CTY-WN

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 
 

 

 

 

 

 

 

 

 

 

   

 

 

         

 

 

 

 

        

 
 
 
 

50 mm air

gap between

heater exterior

and inner fire

chamber

Beginning

of smoke

channel

Top (ceiling)

of fire chamber.

Stove door with

window.

Entrance to fire
chamber.

Cast iron

tray

Ash Drawer

Firewood 

Placement

FIRE CHAMBER

End of smoke

channel.

Cleaning Traps 

(remove caps)

Potential chimney
connection. 
Top mount or rear
mount.

Smoke 
exhaust
direction
(arrow)

Upper air panel -
stainless steel with
holes for air flow.

6

Содержание CTY-WN16

Страница 1: ... Before adding the sauna stones wash them thoroughly Add largers stones towards the bottom of the sauna tray and the smaller stones on top Do not allow the sauna stones to hinder the escape of air flow through the grate The sauna heater warranty is for a period of 1 year to the original purchaser from date of purchase Oven Use Sauna Stones Heats Volume 16 cubic meters 565 cubic feet 790 mm high x ...

Страница 2: ...The air is directed through the holes of the grate which promotes room heating The sauna stove has a heat resisting paint which completely hardens only after the first burning or first initial use At the beginning of the first use or burning the paint softens To not damage the paint try to avoid any contact with any part of the painted surfaces before and during the first burning or use During the...

Страница 3: ... changed For a good draught clean the chimney regularly Ash bin is cleaned before adding wood stoking to promote a good passage for air circulation Do not place ashes in a combustible container Wood burning sauna stoves installations must be approved before using the sauna As we are not aware of any specific codes or regulations which govern wood burning sauna stoves Before installing the wood bur...

Страница 4: ...ances stated in item 1 may be further decreased up to a minimum of 5 inches provided that a double layer of protection is used The double layer of protection may be fabricated using two shields described in item 2 in addition to an additional air gap of 1 1 4 inch is provided between each plate and the wood sauna wall DIA 3 4 The distance between the top of the heater and the wood non protected ce...

Страница 5: ...warranty This limited warranty does not cover damages caused by misuse lack of maintenance accident alterations abuse or neglect the installation instructions included with the product and all local and national building and fire codes The wood fireplace must be installed by a QUALITIFIED technician or contractor Installation must be done in accordance with This factory warranty is non transferabl...

Страница 6: ...p ceiling of fire chamber Stove door with window Entrance to fire chamber Cast iron tray Ash Drawer Firewood Placement FIRE CHAMBER End of smoke channel Cleaning Traps remove caps Potential chimney connection Top mount or rear mount Smoke exhaust direction arrow Upper air panel stainless steel with holes for air flow 6 ...

Отзывы: