sauermann Si-VV 3 Скачать руководство пользователя страница 7

8 - Operating instructions

Key operation

Insert the batteries 

• 

Unscrew the batteries compartment 

cover at the back of the device and 

remove the cover.

• 

Put the 3 alkaline AAA LR03 1.5V 

batteries supplied with the instrument.

• 

Carefully respect the polarity.

• 

To close the batteries compartment, 

push the batteries cover back on, 

starting with the upper part. 

• 

Screw the batteries compartment 

cover.

Turn on the instrument

• 

Press & hold the ON/OFF key.

• 

Place the vane probe in front of the 

airvent or correct location to carry 

out the air velocity & temperature 

measurements.

The probe must be placed with 

the arrow in the direction of the 

air flow.

• 

The device displays the air velocity and 

the temperature measurements.

 

Select the unit

• 

With the device turned on.  

• 

Press & hold the HOLD key to switch to 

the required air velocity measurement 

unit: m/s, km/h, fpm, mph.

• 

Press simultaneously ON/OFF & 

HOLD keys to switch to the required 

temperature measurement unit : °C, °F.

Activate/deactivate the wireless 
communication

• 

With the device turned on. 

• 

Press simultaneously ON/OFF & HOLD 

keys to activate or deactivate the 

wireless communicaiton.

• 

When activated, the wireless 

communicaion icon flashes on the 

instrument screen.

• 

The icon becomes fixed when the 

instrument is paired to a tablet or 

smartphone.

Activate/deactivate the Backlight

• 

With the device turned on. 

• 

Press ON/OFF key to activate or 

deactivate the backlight.

Activate/deactivate the Auto shut-off

• 

The device has an automatic shut-off 

set to 10 minutes.

• 

When the device starts, all the 

segments are displayed. During this 

time, press & hold the ON/OFF key to 

enter the “Power down menu“.

• 

Press HOLD to activate/deactivate the 

auto shut-off.

• 

Press & hold the ON/OFF key to exit 

the “Power down menu“.

Display Hold/Min/Max/Live values

• 

With the device turned on and 

measured values are displayed. 

• 

Press HOLD key to successively: 

- Freeze the display of measurement values 

- Display the minimum measured values 

- Display the maximum measured values 

- Restore the live display

KEY

SHORT PRESS

LONG PRESS (3 seconds)

ON/OFF

Backlight ON/OFF

Device ON/OFF

HOLD

Hold / Min / Max / Live value

m/s / km/h / fpm / mph

ON/OFF and HOLD

Wireless communication ON/OFF

°C / °F

Содержание Si-VV 3

Страница 1: ...www sauermanngroup com USER MANUAL Si VV3 VANE THERMO ANEMOMETER...

Страница 2: ...er measuring instrument In addition to the measurement of air velocity and temperature the airflow is also calculated Vane probe with 2 m cable LCD screen Hold Min Max Live value button A B D On Off b...

Страница 3: ...n appears please do not use the device and bring it back to your distributor to ensure your own safety The device must not be used in ATEX zones according to applicable standards Do not use the device...

Страница 4: ...se limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not insta...

Страница 5: ...given by the user Measuring element Air velocity optical detection Temperature NTC Display Integrated 2 line LCD 7 segment monochrome display with backlight Housing ABS PC and TPE IP54 Keypad 1 ON OFF...

Страница 6: ...e Softcase SIACCSC 151 mm 5 94 70 mm 2 76 33 mm 1 3 Vane and Hot wire anemometer 81 mm 3 19 37 90 mm 1 46 160 17 mm 6 3 38 mm 1 5 151 mm 5 94 70 mm 2 76 33 mm 1 3 Vane and Hot wire anemometer 81 mm 3...

Страница 7: ...communication With the device turned on Press simultaneously ON OFF HOLD keys to activate or deactivate the wireless communicaiton When activated the wireless communicaion icon flashes on the instrum...

Страница 8: ...ment Clean the housing with a damp cloth soap suds if it gets dirty Do not use aggressive cleaning agents or solvents 9 Maintenance 10 Warranty Instruments have 2 year guarantee for any manufacturing...

Страница 9: ...mbH Leibnizstra e 6 D 74211 Leingarten T 49 0 7131 399990 F 49 0 7131 399992 info germany sauermanngroup com Sauermann UK Units 7 9 Trident Business Park Amy Johnson Way Blackpool FY4 2RP T 44 0 870 9...

Отзывы: