33
WWW.TOOL-IS.COM
Attention:
The plug must only be connected to a socket with a RCD switch.
17. Machine usage
Switch on the machine using the main switch and the electronics with
the appropriate button, and regulate the power according to the require-
ments.
Place the induction head on the part to be heated, switch on the power
using the button on the handle, and move the induction head according to
the requirements.
Switch off the electronics by pressing the button on the control panel
after use and then switch off the pump and the blower using the main
switch so that everything can cool down together.
18. How to use the machine
Turn on the main switch and the machine
will be immediately operational. If neces-
sary, press button 4 for 10 seconds to
restart.
All LED's will switch off and will
switch on again after a short time. This
time is necessary so that the coolant
can circulate in the unit and the lines. If the LEDs of buttons 1, 2 and 3
fl ash, a fault is present. In this case, the device must fi rst be restarted.
If the problem continues, contact our customer service.