17
dtE
Defrost
termination
temperature
-50-50
℃
/-58-122
℉
8/46.4
7
45
18
IdF
Interval
between
defrost cycles
1-120ore
6
6
6
19
MdF
(Maximum)
length
for
defrost
0-255min
30
20
20
20
dsd
Start defrost
delay
0-99min
Yes
0
0
0
21
DFd
Display
during
defrost
rt, it, Set, DEF
Yes
it
Set set
22
dAd
MAX display
delay
after
defrost
0-255min
Yes
30
30
30
23
Fdt
Draining time 0-120min
Yes
0
2
2
24
dPo
First defrost
after startup
n=after IdF; Y=immed
Yes
n
n
n
25
dAF
Defrost delay
after
fast
freezing
0-23h n 50’
Yes
0.0
0
0
26
Fnc
Fan
operation
mode
c-n,o-n,c-y,o-y
o-n
o-n o-n
27
Fnd
Fan
delay
after defrost
0-255min
10
2
2
28
Fct
Differential
of
temperature
for
forced
activation of
fans
0-50
℃
Yes
10/50
10
50
29
FSt
Fan
stop
temperature
-50-50
℃
/-58-122
℉
2/35.6
20
54
30
Alc
Temperature
Alarm
configuration
rE=related to set; Ab=absolute
Yes
Ab
re
re
31
ALU
MAX.
temperature
alarm
SET-110
℃
/SET-230
℉
110/23
0
50
90
32
ALL
MIN.
temperature
-50
℃
-SET/-58
℉
-SET
-50/-58
0
0
Содержание SMG12F
Страница 3: ...1 FEATURE CHART 1 1 OUTSIDE DRAWING OF SMG12F 2 WIRING DIAGRAM 2 1 SMG12F...
Страница 4: ...3 PARTS DETAILS 3 1 FRONT PANEL THERMOSTAT MAIN SWITCH...
Страница 6: ...DRAIN PAN CONDENSER FAN MOTOR ASSEMBLY FAN COVER CONDENSER FAN MOTOR BLADE CONDENSER FAN MOTOR...
Страница 7: ...3 3 DOOR GASKET Magnetic gasket can be replaced without any tools...
Страница 9: ...Evaporator Defrost Heating Element Evaporator Fan Fan Support...
Страница 19: ...6 2 4 UNSCREW THE FAN SUPPORT 6 2 5 CHANGE THE DEFROST HEATING ELEMENT A UNHOOK THE EVAPORATOR FROM ITS CASING...
Страница 20: ...B TAKE OFF THE ELEMENT AND CHANGE IT 6 3 CONDENSING UNIT 6 3 1 TAKE OFF THE BOTTOM PANEL OF THE UNIT...