INSTALLING THE HOTPLATE

Refer to the nameplate. Verify the fuel type and pressure, which must

match the nameplate specifications. Connecting the hotplate to the

wrong fuel type and/or pressure will compromise the safety and/or

performance of the appliance.

The hotplate must be placed in its final operational position and

leveled front-to-back and side-to-side, with a spirit level, prior to

beginning the gas piping installation. Re-check the level of the unit

at the conclusion of the gas piping installation.

Each gas hotplate is supplied with a separate gas pressure

regulator, which must be installed on the manifold pipe protruding

from the rear of the hotplate. Ensure that the regulator is installed

such that the flow arrow stamped on the body of the regulator points

toward the hotplate. Failure to properly install the supplied regulator

will result in an extremely hazardous condition.

A moisture trap (drip leg) consisting of a tee, 4” nipple pointing down,

and cap must be installed upstream of the gas pressure regulator.

A manual gas shut-off valve may be required by local codes and is,

in any case, strongly recommended. The shut-off valve must be

installed between the gas supply piping and the gas pressure

regulator.

It is the responsibility of the gas piping installer to

identify the code requirement for a shut-off valve.

Shut-off valves, moisture trap and all associated piping must be

supplied by the gas piping installer.

DANGER:

FIRE AND EXPLOSION

HAZARD

NEVER use an open flame to

check for gas leaks. Fire and

explosion may result.

IMPORTANT:

All pipe joints must be checked

for leaks before lighting. Leak

checks should be performed

with a soap and water solution.

WARNING:

FIRE HAZARD

This hotplate is supplied with a

gas pressure regulator.

Failure to properly install the

supplied regulator will result in

an extremely hazardous

condition.

Flow arrow stamped on body

of regulator must point toward

the hotplate.

Vent hole must point UP.

IMPORTANT:

Verify fuel gas type. If the

available fuel does not match

the nameplate specification,

exchange the hotplate for the

correct type. 

IMPORTANT:

The appliance and its

individual manual shutoff valve

must be disconnected from

supply system piping during

any pressure testing of that

system at pressures in excess

of 1/2 p.s.i. (3.5 kPa).

Also, the appliance must be

isolated from the gas supply

piping system by closing its

individual manual shutoff valve

during any pressure testing of

the gas supply piping at test

pressures equal to or less than

1/2 p.s.i. (3.5 kPa).

Содержание SHP2SU-HD

Страница 1: ...apors or liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service and maintenance can cause property damage injury or death Read the installat...

Страница 2: ...on the repair or replacement of any part found by Saturn to be warranted herein Saturn shall bear the normal labor charges for repair or replacement to the extent that such repair or replacement is pe...

Страница 3: ...ure to retain the container for inspection Manufactuer cannot assume liability for damage or loss incurred in transit We will however at your request supply you with the necessary documents to support...

Страница 4: ...Controls AGENCY LISTING INFORMATION This appliance conforms to NSF Standard 4 for sanitation only if installed in accordance with the supplied Installation Instructions and maintained according to th...

Страница 5: ...dried before use Burner and grate surfaces will be very hot when in use Contact will cause severe injury This appliance must be operated with the supplied 4 legs properly installed Do not operate thi...

Страница 6: ...that the flow of combustion and ventilation air will not be obstructed For servicing manufacturer recommends 6 clearance from rear of the appliance to wall Install adjustable legs one on each corner o...

Страница 7: ...gas burners Additionally 1 The gas supply line used to connect the hotplate to the gas supply system must be black iron pipe or other material as approved by local ordinance for gas piping 2 Gas supp...

Страница 8: ...hut off valve must be installed between the gas supply piping and the gas pressure regulator It is the responsibility of the gas piping installer to identify the code requirement for a shut off valve...

Страница 9: ...t to remain lit ADJUST BURNER FLAME Remove all burner control knobs then remove the front panel Turn an individual burner on The right knob controls the front burner the left knob controls the rear bu...

Страница 10: ...HTING THE PILOT LIGHT Before lighting the pilot light smell all around the appliance area for gas Be sure to smell near floor level because some gas is heavier than air and will settle to the floor Fo...

Страница 11: ...r sections of the burner Set the control knob to the desired position The setting can be readjusted at any time Cooking Recommendations Save energy by turning the temperature control knob OFF any time...

Страница 12: ...cabinet Rinse by wiping hotplate cabinet with a clean soft cloth or sponge moistened with clean warm water Dry cabinet by wiping with a clean soft dry cloth Examine burners to be sure the air shutters...

Страница 13: ...Page 12 CLEANING INSTRUCTIONS Continued CLEANING INSTRUCTIONS Continued...

Страница 14: ...ature control Burner or other internal component Contact manufacturer for repairs Pilot will not light Gas supply off Check main unit gas valves Air in lines Turn pilot valve on Attempt to light pilot...

Страница 15: ...vice RESTAURANT _____________________________ LOCATION ___________________________ INSTALLATION DATE ________________________ TECHNICIAN ________________________ SERVICE COMPANY ______________________...

Страница 16: ...Page 15...

Страница 17: ...Page 16...

Отзывы: