14
Flues Regulations
Balanced Flue Siting
Note:
1. Terminal should be positioned to avoid combustion products entering the building
or accumulating in stagnant pockets around buildings.
2. The terminal must be protected by a guard if it is less than 2 metres above ground
level or in a position where any person has access.
3. A heat protection shield should be fitted if the terminal is less than 850mm from a
plastic or painted gutter or less than 450mm from painted eaves.
Saturn Heating recommends as per OFTEC recommendations that the flue should
be a minimum distance of 1 metre from openings so that it does not cause a
nuisance and permits the dispersal of combustion products.
Building Regulations
A
B
C
Northern Ireland
600
600
600
Republic of Ireland
600
600
600
Where the terminal is within 1 metre of any plastic material, such material should be
protected from the effects of combustion products of fuel. There are additional general
requirements in most regulations and standards that the flue must be positioned so that it
does not cause a nuisance and permits the dispersal of combustion products.
Note:
The Building Regulations clearances shown above are the minimum allowed.
Contact Saturn Heating Technical Department for futher advice in this regard.
ALWAYS CHECK FOR ANY BUILDING REGULATIONS AMENDMENTS WHICH
MAY HAVE BEEN ISSUED AFTER THE PUBLICATION OF THIS MANUAL
a) Horizontal from opening,
airbrick, opening window
etc.
b) From an internal or external
corner.
c) Below an opening, airbrick,
opening window etc.
Information supplied by
Book Four, 2010.
Please see note at foot of page.