INSTALLATION (continued) 

GAS APPLIANCE CODE COMPLIANCE 
The installation of gas piping from the outlet side of the gas meter or

 

service regulator to the griddle must be performed by a technician

 

qualified and certified or licensed to install gas-fired equipment. 
A licensed and qualified technician must perform the initial startup and

 

adjustment of this appliance. 
The installation of this gas-fired appliance must conform to local codes,

 

or in the absence of such codes, with the current edition of 
National Fuel Gas Code ANSI Z223.1. 
For use in the State of Massachusetts, this appliance must be installed

 

in compliance with Massachusetts Fuel Gas and Plumbing Code 
CMR 248. 
The installation of this gas-fired appliance must comply with

 

applicable portions of NFPA 96 for ventilation. The current edition of

 

NFPA 96 (Standard for the Installation of Equipment for the Removal

 

of Smoke and Grease Laden Vapors from Commercial Cooking

 

Equipment) specifies ventilation requirements to ensure the removal

 

of exhaust gasses and products of combustion. 

IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE 
THAT THIS GAS GRIDDLE INSTALLATION CONFORMS TO ALL

 

APPLICABLE CODES AND ORDINANCES. 
The  venting  of  this  appliance  must  not  be  obstructed,  nor  may  such

 

venting  interfere  with  the  flow  of  combustion  air  required  for  proper

 

operation of the gas burners. 

Additionally: 

1.

 

The gas supply line used to connect the griddle to the gas

 

supply system must be black iron pipe, or other material as

 

approved by local ordinance for gas piping. 

2.

 

Gas supply piping must be inside 3/4” diameter or greater. 

3.

 

Use pipe sealant made specifically for gas piping on all pipe joints.

 

Apply sealant sparingly to the male threads only. 
Sealant must be resistant to the action of LP gas. 

4.

 

Verify that all supply piping is clean and free of obstructions, dirt,

 

chips and pipe sealant compound prior to installation. 

5.

 

All pipe joints must be checked for leaks before lighting. Leak

 

checks should be performed with a soap and water solution.

 

NEVER CHECK FOR LEAKS WITH AN OPEN FLAME. 

DANGER: 
FIRE AND EXPLOSION 

HAZARD 
NEVER  use  an  open  flame  to

 

check  for  gas  leaks.  Fire and

 

explosion may result. 

WARNING: 
RISK OF INJURY 
Installation procedures must

 

be performed by a qualified

 

technician with full knowl-
edge 
of all applicable gas-fired

 

appliance codes. Failure can

 

result in personal injury and

 

property damage. 

IMPORTANT: 
All pipe joints must be

 

checked for leaks before

 

lighting. Leak checks should

 

be performed with a soap and

 

water solution. 

IMPORTANT: 
Information on the

 

construction and installation

 

of ventilating hoods may be

 

obtained from the current

 

edition of NFPA 96 
Standard for the Installation

 

of Equipment for the Removal

 

of Smoke and Grease Laden

 

Vapors from Commercial

 

Cooking Equipment. 
Copies of this standard are

 

available from the 
Nation Fire Protection Assn.: 

NFPA 
1 Batterymarch Park

 

P.O. Box 9101 
Quincy, MA 02269-9101 

 

IN

S

T

A

L

L

A

T

IO

N

 (C

o

n

tin

u

ed

Page 6 

Содержание ESG-24

Страница 1: ...Instructions to be followed in the event the user smells gas fumes must be posted in a prominent location in the installed kitchen area The information shall be obtained from a local gas supplier WAR...

Страница 2: ...f this price list does not constitute an agree ment or offer to sell product to the possessor Prices are subject to change without notice Prices do not include sales tax All prices are in U S dollars...

Страница 3: ...nspection Manufactuer cannot assume liability for damage or loss incurred in transit We will however at your request supply you with the necessary documents to support your claim TABLE OF CONTENTS WAR...

Страница 4: ...3 FEATURES OPERATING CONTROLS ADJUSTABLE LEG BURNER ASSEMBLIES PILOT LIGHTS PILOT ADJUSTMENT CONTROL VALVE TYPICAL Fig 1 Medium Duty Gas Griddle Features Operating Controls FEATURES AND OPERATING CONT...

Страница 5: ...the supplied 4 legs properly installed Do not operate this appliance if the smell of gas is present Turn off all gas supply valves and move to a remote location to call your manufacturer for service...

Страница 6: ...NOTICE Manufacturer s warranty on this griddle is in effect only when the griddle is installed in accordance with these instructions and local codes and ordinances or in the absence of local codes th...

Страница 7: ...e gas supply line used to connect the griddle to the gas supply system must be black iron pipe or other material as approved by local ordinance for gas piping 2 Gas supply piping must be inside 3 4 di...

Страница 8: ...e shut off valve must be installed between the gas supply piping and the gas pressure regulator Shut off valves moisture trap and all associated piping must be supplied by the gas piping installer It...

Страница 9: ...bs before returning the unit to service ADJUST BURNER FLAME Remove all burner control knobs then remove the front panel Turn an individual burner on Loosen the locking screw on the shutter Turn the sh...

Страница 10: ...o smell near floor level because some gas is heavier than air and will settle to the floor For initial startup and any time the gas supply has been shut off it may take several minutes to light the pi...

Страница 11: ...s from OFF to ON The right knob controls the front burner The left knob controls the rear burner Light the burner by turning the control knob to the ON position until fire forms completely around the...

Страница 12: ...thoroughly cleaned Using a scraper remove all grease and food waste from the grease trough by pushing it down the waste hole and into the grease tray 6 After scraping all cooking waste from grease tro...

Страница 13: ...rior surfaces dry with a soft clean cloth Allow burners to air dry so that interior passages are completely free of water Examine burners to be sure the air shutters are in their proper position Reins...

Страница 14: ...internal component Contact manufacturer for repairs Pilot will not light Gas supply off Check main unit gas valves Air in lines Turn pilot valve on Attempt to light pilot every 15 sec Pilot valve not...

Страница 15: ...information available if calling for service RESTAURANT______________________________ LOCATION _______________ INSTALLATION DATE _________________________ TECHNICIAN______________ SERVICE COMPANY ____...

Страница 16: ...Page 15...

Страница 17: ...Page 16...

Отзывы: