10
4. Press the
or button to display emissivity value or mode.
(For SK-8120)
Select the appropriate emissivity among 0.95, 0.90 and 0.85.
(For SK-8130/SK-8140)
Set the emissivity in 0.01 steps among 0.10 and 1.00.
0.95
: Food such as meat, fish and vegetables
0.90
: Cardboard containers
0.85
: Grills and iron plates
5. If you need other settings, press the button to display
the next setting mode. Repeat the procedures No. 4 an 5 for the
necessary settings.
6. All settings are ended and press the button for at least
1 second. After the measurement, the new settings are
registered.
Measuring Mode Setting (For SK-8130 / SK-8140)
⚫
Continuous measurement mode (
- - - - -
)
During pressing button, continuous measurement can be done and the measured
value is displayed.
⚫
‘PEAK’ (maximum) measurement mode
In the continuous measurement mode (by pressing button), the maximum
temperature during the measurement is displayed.
⚫
‘VALLEY’ (minimum) measurement mode.
In the continuous measurement (by pressing button), the minimum temperature
during the measurement is displayed.
Setting each mode
1. Press the button at least 3 seconds to display the setting modification mode.
2. Press the or buttons to display the characters of the settings.
3. Press the button for at least 1 second. After the measurement, the new
settings are registered.