SATO SK-180GT Скачать руководство пользователя страница 3

 

 

 

Do not use the instrument in dusty environment. Otherwise, the coat of temperature and humidity 

sensors will deteriorate. 

 

If the instrument is used in

 

an

 

electrically noisy environment, the instrument could show unstable 

values and errors in accuracy. 

 

Using the instrument out of its measuring range can cause malfunctions and damages to both the 

main unit and sensors. Use within the measuring range.   

 

Do not leave the instrument in a car, etc.. It may become extremely hot in the car in summer and it 

causes the instrument to malfunction. 

 

Do not wash or wipe this instrument with alcohol, thinner, or any other solvents. If the instrument gets 

dirty, wipe it with a tightly wrung towel that has been dipped in warm detergent water. 

 

If the instrument is not in use for a long period of time, always remove the battery. Otherwise, the 

battery power may be wasted and the battery fluid may leak, resulting malfunctions.   

 

Be careful when using the strap. It may cause an unexpected accident such as accidental suffocation 

around the neck. 

 

Do not swing the instrument with the neck strap, key ring, or carabiner attached. There is a risk of 

unexpected accidents or damage. 

For repairs or calibrations, contact us or the shop that you purchased. 

 

Overview 

The SK-180GT is a handy type heat stress monitor which can measure globe temperature, air 

temperature and relative humidity.   

Compact body, but it has a globe and enables highly reliable measurement. 

 

Features 

 

JIS B7922 class 2 compliant 

Compliant with JIS B7922 class 2 (electronic Wet Bulb Globe Temperature (WBGT) index meter). It 

can be used as a guideline for preventing heat stress in sports activities, daily life, and labor. 

 

Globe is equipped 

The radiation heat (globe temperature) from direct sunlight can be measured. 

 

Potable design   

Compact size to be portable   

 

Supports two types of heat stress prevention guidelines 

Display is switchable between the 

“Heat stress prevention guidelines for exercise (* 1)” and the “Heat 

stress prevention guidelines for daily life (* 2)

”. 

(*1) 

The 

“Heat stress prevention guidelines for exercise” compiled by the Japan Sport Association 

(*2) 

The 

“Heat stress prevention guidelines for daily life” complied by Japanese Society of biometeorology 

 

Содержание SK-180GT

Страница 1: ...INSTRUCTION MANUAL No 8313 00 Heat Stress Monitor Model SK 180GT R 12...

Страница 2: ...daptability to hot environment etc WARNING Never use this instrument in an atmosphere exposed to inflammable gases as it may explode If there is anything you are not clear about this instrument please...

Страница 3: ...l suffocation around the neck Do not swing the instrument with the neck strap key ring or carabiner attached There is a risk of unexpected accidents or damage For repairs or calibrations contact us or...

Страница 4: ...set limit value of the heat stress index a buzzer sounds and the LED lamp flashes to alert Screw hole for a tripod is equipped Useful to mount the tripod at measurement Accessories Carabiner belt atta...

Страница 5: ...key to turn the main unit on Press it again to turn off MENU key Press this key to enter the setting mode SELECT key In measuring mode press this key to switch WBGT setting between outdoor and indoor...

Страница 6: ...ed How to use Loading and Replacing Battery Before using the instrument for the first time install a new battery When low battery mark appears on the display replace the battery to new one Use a screw...

Страница 7: ...section for one second with the buzzer sound and LED lamp flashes enter the measuring mode Have the instrument fully adapt to measuring ambient before measurement The heat index WBGT temperature humi...

Страница 8: ...onment Environment Mark Usage Outdoor mark is not displayed When used outdoor place in the sun Indoor mark is displayed When used indoor or outdoor at the place not in the sun Keylock function To prev...

Страница 9: ...s index of measurement environment can be easily checked The factory setting is set as the Heat stress prevention guidelines for exercise The Heat stress prevention guidelines for exercise 5 steps Alm...

Страница 10: ...mode press the MENU key for longer than 2 seconds Alarm Function The alarm is triggered with sound of buzzer and blinking LED light when the Heat stress index exceeds the set value The factory settin...

Страница 11: ...ding If the alarm sounds take the appropriate actions to prevent the heat stress Please refer to the Reference data for the actions of the heat stress prevention guidelines How to set alarm function P...

Страница 12: ...the Heat stress index is the highest level Danger Press the MENU key for longer than 2 seconds to return to the measurement mode How to install the mounting accessories The instrument can be worn wit...

Страница 13: ...0 2 x TG 0 1 x DB Indoors WBGT 0 7 x WB 0 3 x TG WB Wet bulb temperature TG Globe temperature DB Dry bulb temperature The Heat stress prevention guidelines for exercise compiled by Japan Sports Assoc...

Страница 14: ...on of Heat Disorder During Sports Activities 2013 The Heat stress prevention guidelines for daily life complied by Japanese Society of Biometeorology WBGT Index Risk of occurrence in relation to physi...

Страница 15: ...t work please contact us or the dealer from which the unit was purchased for assistance Trouble shooting Trouble Possible Cause Solution The power cannot be turned on The battery is exhausted Replace...

Страница 16: ...S B7922 Class 2 Operation Ambient 0 to 50 C less than 95 rh no condensing Wind speed 0 3 to 3 0 m s Storage Ambient 10 to 50 C no condensing Power Requirement 3VDC Lithium coin battery CR2032 2 in par...

Страница 17: ...3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan URL http www sksato co jp english...