
339
[ESC+&R] Form Overlay Call
ESC
&R
Parameter
Hexadecimal code
<1B>
16
<26>
16
<52>
16
,aa
Initial value
None
When the power is OFF
The set parameter is not maintained.
Valid range within items
The set parameter becomes invalid.
Valid range and term of
command
Valid range between items
The set parameter becomes invalid.
[Function]
Invoking the contents in memory card with Registration of Form Overlay <&S>.
[Format]
<&R>,aa
-
Parameter
a [Registration Number] = Valid range: 1 to 99
[Coding Example]
<A>
<CC>1
<&R>,1
<Z>
[Supplementary Explanation]
-
Specify slot number registered with Card Slot for Use <CC> prior to this command <&R> by all
means.
-
This command can be combined with different registration No. and printed.
-
When registration No. is not specified, this command will be ignored.
-
If specifying unregistered No., Read/Write error will occur.
-
When registering without specifying window, Vertical Print Position <V> and Horizontal Print
Position <H> will be ignored and V1 and H1 (Start position of drawing area) will be determined.
-
When specifying and registering window, movement with <V> and <H> will be enabled.
Note that when exceeding print area, the portion outside of print area will not be printed.
-
Please note that this command cannot be used without a memory card.
[Notes]
-
Do not power off this product when accessing to the memory. When this product is turned off
while memory accessing, the data in the accessed media may be corrupted.
[Valid Commands]
Print position
<V>
<H>
Содержание SG112 ex
Страница 1: ...For printer model Programming Reference...
Страница 10: ...9 Basic Specifications 513 Connector pin assignment 514...
Страница 45: ...44 Valid Range Area in horizontal direction 8 to 3200 dots Area in vertical direction 8 to 5040 dots...
Страница 106: ...105 CG Times font character set CG Times Font settings 00H to 1FH are control code and not available...
Страница 107: ...106 CG Triumvirate font character set CG Triumvirate Font settings 00H to 1FH are control code and not available...
Страница 221: ...220 MaxiCode can specify from 01H to FFH...
Страница 236: ...235 QR Code Kanji mode Code table...
Страница 237: ...236...
Страница 238: ...237...
Страница 239: ...238...
Страница 240: ...239...
Страница 241: ...240...
Страница 242: ...241...
Страница 243: ...242...
Страница 244: ...243...
Страница 245: ...244...
Страница 246: ...245...
Страница 247: ...246...
Страница 248: ...247...
Страница 249: ...248...
Страница 250: ...249...
Страница 251: ...250...
Страница 252: ...251...
Страница 253: ...252...
Страница 254: ...253...
Страница 255: ...254...
Страница 268: ...267 QR Code Kanji mode Code table...
Страница 269: ...268...
Страница 270: ...269...
Страница 271: ...270...
Страница 272: ...271...
Страница 273: ...272...
Страница 274: ...273...
Страница 275: ...274...
Страница 276: ...275...
Страница 277: ...276...
Страница 278: ...277...
Страница 279: ...278...
Страница 280: ...279...
Страница 281: ...280...
Страница 282: ...281...
Страница 283: ...282...
Страница 284: ...283...
Страница 285: ...284...
Страница 286: ...285...
Страница 287: ...286...
Страница 314: ...313 Notes This command is used to cut remaining label in printer after the commands A 0 or 0 is executed...
Страница 480: ...479 Near Full Release Near Full 0 MB 2 95 MB Remaining 0 95 MB Remaining 1 95 MB...
Страница 491: ...490 Connector Pin Assignment Pin No Name 1 VBus 2 Data D 3 Data D 4 GND...
Страница 494: ...493 Receive buffer size 2 95 MB Near Full Release Near Full 0 MB 2 95 MB Remaining 0 95 MB Remaining 1 95 MB...
Страница 515: ...514 Connector pin assignment Pin no Name 1 VBus 2 Data D 3 Data D 4 GND...
Страница 516: ...Extensive contact information for worldwide SATO operations can be found on the Internet at www satoworldwide com...