background image

 

Page 1 of 

27 

 

EMC Technologies Pty Ltd 

ABN 82 057 105 549 

Unit 3/87 Station Road 
Seven Hills NSW 2147 Australia 
 

Telephone      

+61 2 9624 2777 

Facsimile      

 

+61 2 9838 4050 

Email        

 

[email protected] 

www.emctech.com.au 

 

Melbourne 

176 Harrick Road 
Keilor Park, Vic 3042 
Tel:   +61 3 9365 1000 
Fax:  +61 3 9331 7455 

Sydney 

Unit 3/87 Station Road 
Seven Hills NSW 2147 
Tel:   +61 2 9624 2777 
Fax:  +61 2 9838 4050 

Auckland (NZ) 

47 MacKelvie Street 
Grey Lynn Auckland 
Tel:   +64 9 360 0862 
Fax:  +64 9 360 0861 

 

 
 
 
 
 
 

APPENDIX I 

OF 

TEST REPORT T140704_F 

 
 

USER MANUAL 

   
   

FCC ID:  2ACXQ-MDR-3021AT 

Manufacturer:  Sato Vicinity Pty Ltd 

Test Sample:  RFID Read-Write Reader 

Model Number:   MDR-3021AT 

Serial Number:  Production Prototype 

   

Date:  8

th

 September 2014 

  
 

Содержание MDR-3021AT

Страница 1: ...c 3042 Tel 61 3 9365 1000 Fax 61 3 9331 7455 Sydney Unit 3 87 Station Road Seven Hills NSW 2147 Tel 61 2 9624 2777 Fax 61 2 9838 4050 Auckland NZ 47 MacKelvie Street Grey Lynn Auckland Tel 64 9 360 08...

Страница 2: ...021AT USER MANUAL 1 79 00 001 DOC User Manual MDR 3021AT Desktop Reader Writer Document Number 79 70 001 DOC Version 1 1 Last Changed 08 September 2014 Copyright SATO VICINITY 2014 Commercial in Confi...

Страница 3: ...llation Environment 9 3 2 2 Working with Tags 10 3 2 3 Installation Requirements 10 3 2 4 Tag to Reader Orientation 10 3 3 Hardware Installation 11 3 3 1 Connecting a Reader to a Computer using USB 12...

Страница 4: ...enance equipment Except for externally accessible fuses there are no user serviceable parts in any Reader There is no requirement to remove the cover of the Reader Removal of the Reader cover by unaut...

Страница 5: ...rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate r...

Страница 6: ...rranted against defects in design materials and workmanship for a period of 1 year from the date of purchase by the original owner Any liability with respect to components including purchased or free...

Страница 7: ...ment It includes the Model Number P N D C S N and MLC PJM Phase Jitter Modulation or PJM is a registered Trade Mark of Sato Vicinity PJM StackTag Registered Trade Mark for Sato Vicinity s StackTag tag...

Страница 8: ...DR 3021AT offers connection to a PC via Ethernet or USB and is simple to set up and use straight out of the box The MDR 3021AT Desktop Reader is suitable for all RFID applicable environments including...

Страница 9: ...r Install exe Documentation Folder Contains various PDF documents including User Manuals Programmer information CD ReadMe txt Text file describing all the files on the CD Reader Manager Install exe Th...

Страница 10: ...NIG Do not operate this Reader in an environment which contains flammable or explosives gases or fumes Sato Vicinity s RFID Readers communicate with data carriers RFID inlets labels and tags using the...

Страница 11: ...ngths to communicate with a Reader and as a result they may not communicate with some Readers or have to be closer to a Reader antenna to function Please consult Sato Vicinity or your support organisa...

Страница 12: ...orrect Tag Orientation 3 3 Hardware Installation MDR 3021AT User Interface Panel Step 1 Connect a low voltage power pack to the Reader The connection to the power source is realized via a low voltage...

Страница 13: ...er software Step 3 Test the Reader with a known working RFID tag The green LED will light when an RFID tag is successfully read 3 3 1 Connecting a Reader to a Computer using USB Connect the MDR 3021AT...

Страница 14: ...oftware Installation Reader Manager is a graphical application for Windows It provides a platform for reader setup configuration demonstrations testing and application development When it is run Reade...

Страница 15: ...install if required In this case the following window is shown Click OK PJM Reader Manager Setup Python runtime installation popup You will be prompted for the directory to install the Python system...

Страница 16: ...ed with the current version you can force a reinstall by manually ticking the checkbox Next to the application You will be prompted for the directory to install Reader Manager The default location is...

Страница 17: ...on window 3 4 2 Connecting to a Reader A Reader provides Ethernet and USB device interfaces to allow for client connection The USB interface uses TCP IP networking over USB as the protocol This allows...

Страница 18: ...llowing steps 1 In Found New Hardware Wizard tick Yes this time only to search for software and press Next 2 In What do you want wizard to do tick Install the software automatically and press Next 3 W...

Страница 19: ...t the green status bubble to the left of the reader turns into a green arrow the IP address of the reader will be displayed in the bottom right corner of the Reader Manager window Dynamic Reader List...

Страница 20: ...The Addition of more tags will cause more squares to progressively populate with the tag s ID number and the number of times the tag was sighted Removing a tag will cause the tag to Expire turning the...

Страница 21: ...you can enter the name you would like the Reader to be identified as This is useful in a large reader networks where you may need to manage many readers The name entered in the Customer ID field is t...

Страница 22: ...k box and enter the required IP Address Subnet mask Default Gateway Press the Enter key on your keyboard then Click the Save button to the right to save your changes to the reader Power cycle the read...

Страница 23: ...tting Tick the Powering Field box Reader faulty Contact your local supplier for support The tag type is incompatible with the reader Use the appropriate tag type for the reader contact your local supp...

Страница 24: ...21AT USER MANUAL 23 79 00 001 DOC 5 Document Revision History Version Date Person Change Ver 1 0 22 Aug 2014 Steve Antonio Initial Release of 79 70 001 DOC Ver 1 1 09 Sep 2014 Steve Antonio Document R...

Страница 25: ...ost Requirements Windows XP SP2 500 MHz CPU 128 MB RAM Environmental Operating Environment Indoor use Temperature Range 10 C to 45 C ambient Humidity 10 to 80 non condensing Reader Placement Can be pl...

Страница 26: ...uirements concerning EMC Article 3 1 b Standard Test Report Test Report issued by Regarding EN 301 489 1 v1 6 1 T140606_E T61109_E EMC Technologies EMC EN 301 489 3 v1 4 1 T140606_E T61109_E EMC Techn...

Страница 27: ...y Regarding AS NZS CISPR 22 2006 T140606_E EMC Technologies EMC emissions AS NZS 4268 2012 T140606 EMC Technologies Radio ARPANSA Radiation Protection NA MC Technologies SAR Year in which C Tick mark...

Отзывы: