145
10.2 2-D Code
Printer
CL408e/412e
M-8400RVe
CL608e/612e
M-5900RVe
M-10e
M-8485Se/90Se/60Se/59Se
M-84Pro-2/3/6
LC408e/412e
10.2 ESC+BV MAXI Code
ESC+BV
HEX Code
ESC
BV
Parameter
<1B>
16
<42>
16
<56>
16
a,b,c,ddddddddd,eee,fff,n~n
Default Value
NIL
Valid Range &
Terms of
Command
When Power is Switched Off
The set parameter is not maintained
Valid Range within Items
The set parameter becomes invalid
Valid Range between Items
The set parameter becomes invalid
[Function]
To specify 2-D Code MAXI code
[Format]
<BV>a,b,c,ddddddddd,eee,fff,n~n
● Parameter
a {Symbol Number} = valid range : 1~8
b {Symbol Digit Number} = valid range : 1~8
c {Mode} = 2 : for distribution
3 : for distribution
4 : standard symbol
6 : for scanner
d {Postal Code} = valid range : 0~999999999 (mode 2)
000000~999999 (mode 3)
* Max 9 digits when at mode 2 (numeric)
* 6 digits is fixed when at mode 3 (specify capital letters for
alphabet)
e {Country Code} = valid range : 001~999
f {Service Class} = valid range : 001~999
n {Low Priority Message} = Alphanumeric / Symbol
[Coding Example]
<A>
<V>100<H>200
<BV>1,1,2,123456789,001,002,SAHTHA
<Q>2
<Z>
[Supplementary Explanation]
1.At MAXI code, the printed MAXI code size will not change from the print data number.
2.Printing will not be performed if the specified parameter not indicated cannot fixed to the print data number.
3.When mode4, 6 is specified, the print data number must be specified at 12 above. If the print data number is specified at less than 11, the printed MAXI
code will become unreadable at the scanner.
Mode
Service Class
Country Code
Postal Code
Max Print Data Size
Numeric Only
Mixture of
Alphanumeric
2
3 digits fixed
(numeric only)
3 digits fixed
(numeric only)
Max 9 digits
123
84
3
6 digitis fixed (mixture of
alphanumeric)
4
Omit
138
93
6
MAXI Code