background image

 

 

Rear Panel 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  AC power input terminals 

: Used to supply power to the unit via the power cable included with the product. 

 

Power    : Terminals to which the power cable and the ground wire are connected 
(100 VAC)   


ZG 

  Earth 

 

  Fuse              : 1 amp fuse in the power input circuit 

  Power switch:  Used to turn on or off the unit. Turning off the unit shuts down all the functions of the 

unit. After power-on, the unit is in the initialization state for five seconds. 

  Connection terminal bank 1: Terminals for input signals received from the sensor 

  Wind speed and 

direction sensor 

: Connect the output cable from an anemometer to input the wind speed 

and direction data. 




 

 

 

G     

 

  Connection terminal bank 2: External output terminals, optional function 

A   

RS-422 

Digital signal output terminals 

B   
 

   

+    Wind speed:   

(0 - 1 V) 

Wind speed analog signal output terminals   

-   
 

   

+    Wind direction: 

(0 - 1 V) 

Wind direction analog signal output terminals   

-   

 

  Connection terminal bank 3: Contact terminals used to output alarms 

   

 

Alarm 1:  Contact signal is output if the wind speed alarm 1 enters the output state. 

     

Alarm 2:  Contact signal is output if the wind speed alarm 2 enters the output state. 

     

Alarm 3:  Contact signal is output if the wind speed alarm 3 enters the output state or the wind   

                              direction alarm enters the output state. 

 

Connection terminal bank 1

 

 

AC power input terminals

 

 

Fuse

 

 

Power switch

 

 

Connection terminal bank 2

 

 

Connection terminal bank 3

 

Power 

Power 

Earth 

Wind Speed & 

Direction Sensor 

Wind Speed 

Wind Direction 

(0-90m/s) 

(0-540deg) 

Alarm No. 1 

Alarm No. 2 

Alarm No. 3 

Содержание WVAT6D0-3-10

Страница 1: ...Instruction Manual No 7910 50 Wind Speed Wind Direction Indicator with Alarm Model WVAT6D0 3 10 3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan URL http www sksato co jp english EW JA12001 2 ...

Страница 2: ...irection Sensor 2 Input voltage Wind speed Photoelectrical pulse 60 pulses per one propeller rotation Number of propeller rotation 3081rpm at 60m s Wind direction Brushless potentiometer 0 to 360 3 Display output Display element Wind speed 7 segment red LED 4 digits 3 digits for data Instant upper Mean lower Height of character 14 2mm Wind direction Red LED 16 pcs Azimuth position 16 Azimuth red L...

Страница 3: ...ion 0 to 540 0 to 1V Mean wind direction 0 to 540 0 to 1V Available to set the output span by every 10m s Output impedance less than 500ohm Digital output Signal system RS 422 Output 1 channel Requirements Transmission speed 300 1200 2400 4800 9600 14400 19200 bps Data length 8 bit Start bit 1 bit Stop bit 1 bit Parity None Flow control None Output elements Instantaneous wind direction Instantaneo...

Страница 4: ...default setting For details on changing the specifications please contact our sales representative 100VAC Wind direction Instant or Mean 0 to 540 0 to 1VDC WVAT6D0 3 11 Wind speed direction indicator with alarm Wind speed Instant or Mean 0 to 90m s 0 to 1VDC Option W639 ED1 Wind speed direction sensor Alarm 1 Non voltage Make contact Wind speed Instant or Mean Alarm 2 Non voltage Make contact Wind...

Страница 5: ...4 III Handing III 1 Outer dimensions unit mm ...

Страница 6: ...dots Alarm lights Turns on when the alarm is activated Operation buttons Used to configure various settings such as alarm setting values Buzzer port A buzzer sound is heard from this port Wind direction indicator lights Indicate wind direction items instantaneous mean The yellow light indicates the instantaneous wind direction and the red light indicates the mean wind direction ...

Страница 7: ...nnection terminal bank 2 External output terminals optional function A RS 422 Digital signal output terminals B Wind speed 0 1 V Wind speed analog signal output terminals Wind direction 0 1 V Wind direction analog signal output terminals Connection terminal bank 3 Contact terminals used to output alarms Alarm 1 Contact signal is output if the wind speed alarm 1 enters the output state Alarm 2 Cont...

Страница 8: ...h Short circuit RS422 Wind Speed 1V Wind Direction 1V Alarm 1 10m s Alarm 2 20m s Alarm 3 30m s Wind Speed Direction Indicator with Alarm WVAT6D0 3 10 Wind Speed Direction Sensor W639 ED1 Optional functions Alarm output Initial setting ...

Страница 9: ...5 Auto return function While in the check or setting mode if no button is pressed for 60 seconds or so the unit automatically returns to the monitor mode If the setting operation is not completed within 60 seconds the value is not changed III 6 Display mode III 6 1 Monitor mode Wind speed data are displayed in the upper and lower 7 segment LEDs Wind direction data wind direction indication are dis...

Страница 10: ...a set here apply to alarms 1 2 and 3 0 No alarm output 1 Determined by the instantaneous wind speed 2 Determined by the mean wind speed a2 A2 Wind speed alarm 1 setting value Wind speed threshold value to determine the alarm conditions Setting range 5 to 90 m s 0 No alarm output a3 A3 Wind speed alarm 2 setting value Wind speed threshold value to determine the alarm conditions Setting range 5 to 9...

Страница 11: ...tting value for the wind direction alarm confirmation time The alarm is activated if the wind direction readings remain within the angle range set by section 1 or 2 for this time period Setting range 0 to 60 sec b3 Setting value for the wind direction alarm cancellation time After activation the alarm is cancelled if the wind direction readings remain outside the angle range set by section 1 or 2 ...

Страница 12: ...ng value on the lower LED starts flashing to indicate that the value can be changed Use the UP or DOWN button to increase or decrease the numerical value to the desired value When the new value is correct press the BUZZER ENT button to confirm The value stops flashing to indicate that the setting value has been successfully updated The unit returns to the state of 2 above allowing other settings t...

Страница 13: ...nt setting value Ending angle for the wind direction alarm section 1 Setting range 0 to 359 a0 A0 Wind direction alarm section 2 start point setting value Starting angle for the wind direction alarm section 2 Setting range 0 to 359 b1 Wind direction alarm section 2 end point setting value Ending angle for the wind direction alarm section 2 Setting range 0 to 359 b2 Setting value for the wind direc...

Страница 14: ... signals are output from the external output terminal at a rear panel Analog output terminal Note that the factory settings are 0 to 90 m s 0 to 1 VDC 0 to 540 0 to 1 VDC However it is available to ship with the range designated by the customer The analog output range of the wind speed can be custom specified between 10 and 90 m s in 10 m s increments and the wind direction can be custom specified...

Страница 15: ...tes CR LF Dummy signal 00H h STX 02H Instantaneous wind direction XXX 0 to 359 Instantaneous wind speed XX X 0 0 to 99 9 m s Instantaneous max wind speed XX X 0 0 to 99 9 m s Instantaneous max wind speed within the lap time of the latest 10 or 2 min updated in every 5 seconds Instantaneous minimum wind speed XX X 0 0 to 99 9 m s Instantaneous min wind speed within the lap time of the latest 10 or ...

Страница 16: ... output ON LED light blink lit Buzzer sounding Wind direction The alarm is activated if the wind direction readings remain within the angle range set by section 1 or 2 for at least the time specified as the wind direction alarm confirmation time Contact output ON Wind direction alarm is output from the alarm 3 contact The wind direction LEDs within the set range of section 1 or 2 start blinking Ca...

Страница 17: ...low intermittent sound Green slow blinking Alarm 2 Wind speed Fast intermittent sound Yellow fast blinking Alarm 3 Wind speed Continuous sound Red continuous light Wind direction No sound LED of wind direction indication is blinking in the alarm section ...

Страница 18: ...ind speed display section Instantaneous wind speed fixed 15 b5 Display item in the lower wind speed display section Mean wind speed fixed 16 b6 Display item in the wind direction display section Instantaneous wind direction 17 Wind speed direction display update time 1 sec fixed 18 Wind speed direction instantaneous value processing Instantaneous value 19 Wind speed direction mean value processing...

Отзывы: