For battery-operated model (Quartz type)
●
Recording cylinder
●
Loading batteries
・
To open the lid of the battery compartment, pull the knob outside.
・
Insert two C size batteries into the battery compartment with the correct
polarities (+/−).
・
Close the lid while pulling the knob outside.
●
Verifying operation
Cylinder starts rotating soon after the batteries are installed. Confirm that LED
(green) is blinking.
Knob
●
Checking battery condition with LED
LED (green) goes out when the voltage of the battery becomes 2.2VDC
±
10% or
less under normal ambient. At this time, replace the batteries to the new ones
immediately.
NB : Recording cylinder stops operation in approx. one month after the LED
goes out under normal ambient.
●
Changing cylinder speed
The cylinder speed switch is set for 7-day
operation at factory shipment.
Set the switch at the top of cylinder to 1D or
32D for 1-day or 32-day operation. (Fig. 2)
NB
: Be sure to replace the chart according
to its recording period.
Fig. 1
Battery
compartment
Knob
LED (Green)
Cylinder speed switch
Fig. 2 Cylinder speed switch