INTRODUCTION 

Thank you for purchasing the SK-110TRHII series digital thermohygrometers. 

-  These products are designed to measure temperature and humidity of atmosphere.  Do not use 

these for other purposes. 

-  Read this manual thoroughly before use.  Keep the manual in safe place for future references. 

 
 

 

WARNING

  

-

  Model SK-110TRHII series are not of explosion proof types.  Never use them to measure gases 

including flammable gases.    

 
 

DANGER – EXPLOSIVE  There is a fear of explosion – 

 
 
 

CAUTIONS 

 

Observe the following points for the proper use of instrument

  This instrument is delicately made.  Be careful not to drop it or give shocks to it. 

  The probe and main body are unified.   The probe cannot be unfastened from the main body. 

  Never disassemble or alter the unit to avoid the causes of trouble. 

  These instruments are not waterproof.  Never let them get wet.  

  Never use the unit in an environment other than normal atmosphere.  

  Don’t use the unit at a place exposed to direct sunlight or near heaters.  Doing so may result in 

failure or case will be deformed. 

  Do not use the unit in the circumstances where electric noises are generated.  Doing so may 

result in unstable display or large errors. 

  Don’t pull strongly, bend or bind the sensor cord.  Don’t put heavy things on the sensor cord or 

modify the sensor cord and the cord will be damaged.    

  If the unit is not used for a long period of time, be sure to remove the batteries.   Otherwise, 

liquid may leak and it results in failure. 

  Do not dispose the used batteries in a fire. 

  Keep the batteries out of reach of children. If swallowed the battery accidentally, consult a 

doctor immediately. 

  Don’t wash or wipe the unit with alcohol, thinner or other detergent etc.  When the unit is 

stained wipe it with the following cloth.  Dip a cloth into lukewarm water in which detergent is 
dissolved and squeeze it tight. 

  When the condensing occurs during use of the unit, turn the power off and let the humidity 

sensor naturally at normal temperature. 

  Type 2 has a pointed probe. Be careful in use as the sharp tip could cause accidental injuries.  

  Do not bend the sensing stem or flexible tube in the type 2, they 3 and type 4.  

Содержание 8111-00

Страница 1: ...INSTRUCTION MANUAL SK 110TRH Series Digital Thermohygrometers...

Страница 2: ......

Страница 3: ...r near heaters Doing so may result in failure or case will be deformed Do not use the unit in the circumstances where electric noises are generated Doing so may result in unstable display or large err...

Страница 4: ...from which the unit was purchased FEATURES Measuring operation is simple by pressing the POWER ON OFF button Large LED font height 13 mm for easy reading Low battery mark blinks when the batteries ar...

Страница 5: ...links at one second interval when the batteries are exhausted Replace the batteries with new ones Probes Type 1 Standard type General purpose monitoring environment in computer operation rooms factori...

Страница 6: ...sor cap 9 Sensor filter built in 4 Humidity sensor HSK 10 Sensor cap L 5 Temperature sensor Thermistor 12 Sensor cap S 6 Sensing stem 13 Telescoping type stem HOW TO USE Loading batteries 1 To remove...

Страница 7: ...dity values will be displayed being ready for measurement 2 Press POWER ON OFF button again for more than 1 second and the display will disappear and power will be off NB The probe and unit are unifie...

Страница 8: ...on Use the glass filter option in case circumstance for measurement is not good enough due to dusts etc Remove the sensor cap and put the glass filter over the sensor section Set the rubber cushion on...

Страница 9: ...ng condition Main body 0 to 50 C less than 80 rh no condensing Probe 10 to 60 C no condensing Sampling time About 1 sec Functions Low battery mark dual display for temperature and R humidity Power req...

Страница 10: ...8 ACCURACY OF R HUMIDITY Humidity rh Calibration may not be accurate Temperature C...

Страница 11: ......

Страница 12: ...3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan TEL 81 0 3 3254 8117 FAX 0 3 3254 8123 URL http www sksato co jp english R 01...

Отзывы: