- Do  not  touch  the  measurement  window  with  a  sharp  or  hard  object.  Doing  so  may  damage  the  lens, 

causing loss of measurement accuracy.   

 

- Do not use this unit in an environment where electrical noise is generated. Doing so may result in unstable 

display or larger errors. Also, do not bring the unit close to a charged object. 

 
- Never use the unit in water.     
 
- If this unit is not going to be used for a long time, always remove the battery from the unit. Otherwise, the 

battery may leak fluid, resulting in failure. 

 
- Do not dispose of the used battery in a fire. 
 
- Keep the battery out of the reach of children. If you have swallowed the battery accidentally, consult a 

doctor immediately. 

 
- For environmental conservation purposes, dispose of the used battery in compliance with local rules and 

regulations. 

 
- Do not wash or wipe this unit with alcohol, thinner, or other organic solvents. If the unit becomes dirty, 

wipe it with a tightly-wrung gauze or the like that has been dipped in warm water with neutral detergent. 

 
- Do not wipe the temperature measurement section (infrared lens) directly with gauze. For details, refer to 

"Maintenance". 

 
- Glass  does  not  transmit  wavelengths  used  by  this  thermometer.  Therefore,  when  an  object  is  placed 

beyond glass, this unit detects the temperature of the glass and displays its temperature reading. 

 
- If the ambient temperature fluctuates excessively, the measurement accuracy may be affected. Wait for a 

while for the unit to properly adapt to the ambient temperature. For a change of temperature of 10°C or 
more, wait for at least 30 minutes before measurement. 

 
- Never grasp the measurement spot guide (trumpet-shaped section) during measurement, or the 

measurement accuracy may be affected.   

 
   

 

6.    Notes on Storage 

 

-The  storage  ambient  for  the  PC-8400

is  -10  to  50°C  and  less  than  90%RH.  It  is  recommended  to  be 

stored with a desiccant at around room temperature. 

 
- Leaving this unit inside a car under the full sun in a hot climate will cause it to become extremely hot, 

possibly resulting in failure. Do not leave it in such hot places. 

 
 
 

Содержание 1081-00

Страница 1: ...Instruction Manual for No 1081 00 Pocket Sized Infrared Thermometer Model PC 8400Ⅱ ...

Страница 2: ...ut touching the object 3 Features Non contact instant temperature measurement The temperature on the surface of the object can be measured instantly by simply pressing the Scan key on the PC 8400Ⅱ Pocket sized infrared thermometer The PC 8400Ⅱ fits in the pocket assuring excellent portability Adjustable Emissivity Emissivity specific to the material of the object to be measured can be set Spot Gui...

Страница 3: ...of the unit 2 Scan key Pressing this key starts measuring the surface temperatures of the object The power is automatically turned off approximately 15 seconds after releasing the Scan key automatic power off function 3 Mode key Pressing this key in the measurement mode normal measurement status allows the following to be set a MAX value highest temperature display function b MIN value lowest temp...

Страница 4: ...For details on how to change the emissivity see Emissivity Setting Function 5 Notes on Use Be sure to observe the following precautions in order to use this unit correctly Do not use this unit as a clinical thermometer This is a non contact thermometer Do not let the unit touch the object to be measured If the unit touches a hot object it may result in measurement errors or failure Never disassemb...

Страница 5: ...wrung gauze or the like that has been dipped in warm water with neutral detergent Do not wipe the temperature measurement section infrared lens directly with gauze For details refer to Maintenance Glass does not transmit wavelengths used by this thermometer Therefore when an object is placed beyond glass this unit detects the temperature of the glass and displays its temperature reading If the amb...

Страница 6: ...can key to start measuring Pressing the Scan key turns on the unit 2 Release the Scan key to cancel measuring Releasing the Scan key turns off the unit after approximately 15 seconds displaying OFF Automatic power off function 3 With the PC 8400Ⅱ the ratio of D the distance to the object to S the diameter of the measurement spot on the object is 6 1 For details see Notes on Measurement CAUTIONS Do...

Страница 7: ...it continuous measurement When you release the Scan key the latest MIN value remains displayed on the LCD 3 To clear this MIN value press the Scan key again This returns to the MIN value display function 4 To cancel the MIN value display function press the Mode key while the MIN value is being displayed MAX value highest temperature display function 1 To set this function press the Scan key once a...

Страница 8: ...he emissivity value on the LCD will go off if the automatic power off function is activated before pressing the Mode key resulting in no change to the value The table below lists the typical materials with their emissivity Note that the emissivity varies with the temperature and surface condition of the object the values are given for reference only 1 Emissivity Table The table below lists the typ...

Страница 9: ... thermometer continuously to measure a high temperature 200 C or more object at a short distance 30 mm or less for a long time three minutes or more may cause a drop in the performance of the infrared lens When measuring a hot object of 200 C or more the distance should be 30 mm or more and operation should be completed within a short time 2 There is also the risk of burning your hand by accidenta...

Страница 10: ...with water or detergent Doing so may affect the performance of the lens and cause inaccurate measurements 16 Error Codes Error Code Description Action to be taken Measured temperature exceeds 250 C Immediately stop measuring the object which is too hot Otherwise the sensor may fail The measurable temperature range is from 60 to 250 C Measured temperature is lower than 60 C Immediately stop measuri...

Страница 11: ...adings Wrong emissivity is set Set the proper emissivity of the object to be measured by referring to the table of emissivities The surface of the object to be measured is frozen or covered with condensation or dust Clean the surface of the object Condensation or dust on the surface of the object will affect the readings The readings are unstable The battery power is insufficient Replace the batte...

Страница 12: ...C Lower than 80 RH no condensing Storage ambient 10 to 50 C Lower than 90 RH no condensing Functions Adjustable emissivity ε 0 05 to 1 00 MIN minimum memory data MAX maximum memory data LOCK continuous measurement Auto power off Power requirements Lithium coin battery 1 pc CR2032 Battery life About 20 hours 20 times of 60 min measurement by LOCK function at 20 C Materials Main unit ABS resin Trump...

Отзывы: