77 

 

 

Appendix

 

 

Emissivity table 

 

Material 

Temperature

°C

 

Emissivity 
approximation 

Metal 

Aluminum 

Polished aluminum 

100 

0.09 

Commercial  aluminum 
foil 

100 

0.09 

Electrolytic 
chromeplate alumina 

25

600 

0.55 

Mild alumina 

25

600 

0.10

0.20 

Strong alumina 

25

600 

0.30

0.40 

Brass 

Brass mirror (highly   
polished) 

28 

0.03 

Brass oxide 

200

600 

0.61

0.59 

Chrome 

Polished chrome 

40

1090 

0.08

0.36 

Copper 

Copper mirror 

100 

0.05 

Strong copper oxide 

25 

0.078 

Cuprous oxide 

800

1100 

0.66

0.54 

Liquid copper 

1080

1280 

0.16

0.13 

Gold 

Gold mirror 

230

630 

0.02 

 

www.

GlobalTestSupply

.com

Quality SATIR Products Online at:

[email protected]

Содержание E8-GN

Страница 1: ...nformation displayed on the LCD Monitor p 18 TrademarkAcknowledgments SDSistrademarksofSDSLTD Microsoft WindowsandWindowslogoiseitherregisteredtrademarksortradema rksofMicrosoftCorporationintheUnitedS...

Страница 2: ...s working with the camera from each analysis settings tousing the camera svarious analysis tools Shooting Explains how toreview recorded images erase images and playback voice memos Playback and erase...

Страница 3: ...Local Settings 21 Basic Functions 23 Using the LCD Monitor 23 Selecting Menus and Settings 24 Resetting the Setting to Default 26 Shooting 27 IR Camera Adjustment 27 Focus 27 Manual Focus 27 Display M...

Страница 4: ...Download via SD Card 58 Connecting and Download 59 Connecting to the dock 59 Charging via the dock 60 Connecting to a Monitor 61 Connecting to a computer 62 Connecting to a computer 61 Installing Dri...

Страница 5: ...tsinthefailureofanimagetobe recordedortoberecordedinaformatthatismachinereadable WarningAgainstCopyrightInfringement Safety Precautions Beforeusingthecamera pleaseensurethatyoureadand understandthesaf...

Страница 6: ...Stop operating immediately if it is dropped or the casing is damaged Failure to do so may result in fire or electrical shock Immediately turn the IR camera s power off remove the IR camera battery or...

Страница 7: ...r expose them to directly to flame or heat Neither should you immerse them in water Such exposure may damage the batteries and lead to the leakage of corrosive liquids fire electrical shock explosion...

Страница 8: ...nd when the IR camera is not in use to avoid fires and other hazards Continuous use over a long period of time may cause the unit to overheat and distort resulting in fire Do not use the battery charg...

Страница 9: ...era Stop using the camera immediately if you detect condensation Continue to use may damage the IR camera Remove the PC card and battery or a household power source from the IR camera and wait until m...

Страница 10: ...igger Illuminator Visual CCD Camera Focus Ring Thermal Lens Lens Locking Ring Multi function Dock E8 N is not equipped with illuminator visual CCD camera and laser pointer www GlobalTestSupply com Qua...

Страница 11: ...11 Component Guide Back Bottom View Key Pad LCD Display Battery SD Card Cover USB Terminal Video out Terminal www GlobalTestSupply com Quality SATIR Products Online at sales GlobalTestSupply com...

Страница 12: ...on Dock Menu Enter Key Cursor Key Cancel Key Freeze Activate Power Switch Auto Adjust Key Power Indicator USB Terminal Video Output Terminal Power Terminal www GlobalTestSupply com Quality SATIR Produ...

Страница 13: ...omponent Guide Bottom Connectors Lock Battery Lock SD Card Slot Battery insertion slot Multi connector Multi connector www GlobalTestSupply com Quality SATIR Products Online at sales GlobalTestSupply...

Страница 14: ...battery pack is charging and it turns green when charging is complete After charging unplug the battery charger and remove the battery pack This is a lithium ion battery pack so there is no need to di...

Страница 15: ...e first time 1 Check if the power is off and slide the battery cover in the direction of the arrow 2 Insert the battery pack Insert the battery in the direction of the arrow 3 Insert SD card Insert th...

Страница 16: ...therwise the IR camera may not recognize the SD card Battery Status Symbols The following icons indicate the battery status on the LCD display Sufficient battery charge Low battery Replace or recharge...

Страница 17: ...key pad and put your forefinger in front of the definable trigger 2 Press and hold the power switch for 3 seconds The power indicator lights green 3 After a while a startup image will appear on the s...

Страница 18: ...tion view About the operation indicator The operation indicator shows the current operation status of the camera Upper limit of color scale Operation indicator Battery Charge Time Color scale Reading...

Страница 19: ...eprents the current analysis tool is profile ISO Represents the current analysis tool is isotherm analysis E Current Emissivity value SD card has been inserted Bluetooth headset has been paired The st...

Страница 20: ...p menu 3 Press the UP or DOWN arrow on the omni selector to select Date Time then press the MENU ENTER key 4 Setting Date and Time Press the UP or DOWN arrow on the omni selector to select anitem to c...

Страница 21: ...up menu 3 Press the UP or DOWN arrow on the omni selector to select Local Setup then press the MENU ENTER key 4 Local Setup Press the UP or DOWN arrow on the omni selector to select afield to change P...

Страница 22: ...ormat of the video output of the camera PAL or NTSC Temp unit Sets the format of the displayed temperature unit of the camera C or F Distance unit Sets the format of the displayed distance unit of the...

Страница 23: ...ow the instructions below 1 Open the LCD displayer in the direction of the arrow 2 Aim the IR camera at a subject 1 For a better temperature measurement please do make the subject in center of the ima...

Страница 24: ...T or RIGHT arrow on the omni selector 3 Press the UP or DOWN arrow on the omni selector 4 Press the MENU ENTER button Selecting Menus and Settings 1Menu 2Select a function item using File Menu Analysi...

Страница 25: ...e operation and setting contents The menu items are different according to different type of camera 4 Change the settings using 3 Select setting contents using Exit www GlobalTestSupply com Quality SA...

Страница 26: ...default 1 Turn off the IR camera p 17 2 Press and hold the power switch and C key for seconds The data in storage will not be deleted when you reset the menu and button operation settings to default...

Страница 27: ...Manually Focus 1 Aim that the IR camera at the subject 2 Turn the focus ring to focus on the target 3 Do not stop turning until the image is clear www GlobalTestSupply com Quality SATIR Products Onli...

Страница 28: ...ct the IR Visible menu 3 IR Visible Setup Press the UP or DOWN arrow on the omni selector to select anitem to change Press the LEFT or RIGHT arrow on the omni selector to set the values 4 Press UPor D...

Страница 29: ...seudo color Vision Only In this mode you can see the image with full color But you can not use any analysis tools to analyze the target Duo Vision In this mode you can see the background image is full...

Страница 30: ...e area right C RIGHT About the IR Visible settings IR Percentage Sets the ratio of IR images and Visual images The value is from 1 to 100 In the IR and Vision Mix mode you can press UP or DOWNarrow to...

Страница 31: ...31 The items above are activated only in Duo Vision mode www GlobalTestSupply com Quality SATIR Products Online at sales GlobalTestSupply com...

Страница 32: ...uto adjust The IR camera will automatically adjust the brightness and or contrast and calibrate when you press the A key for the first time If you press A key a second time in 15 seconds the camera wi...

Страница 33: ...u 1 Press the MENU ENTER key 2 Press the UP or DOWN arrow on the omni selector to select the Manual Adj menu 3 Setting Level and Span Press the UP or DOWN arrow on the omni selector to select anitem t...

Страница 34: ...ress the LEFT or RIGHT arrow to choose the palette 3 After this operation press the MENU ENTER key to save changes or press the C key close the menu without saving The camera provides 6 kinds of palet...

Страница 35: ...r to select Camera Setup then press the MENU ENTER key 4 Set the Image Settings Press the UP or DOWN arrow on the omni selector to select anitem to change Press the RIGHT or LEFT arrow on the omni sel...

Страница 36: ...d contrast of the the image shown on the screen are adjusted automatically Level and span The brightness and contrast is adjusted automatically Level The brightness is adjusted automatically None The...

Страница 37: ...R key 3 Selecting measurement range for different lens After selecting the Range field press UP and DOWN arrow on the omni selector at the same time to change the measurement range for different lens...

Страница 38: ...eze a thermal image by pressing the S key on the keypad 1 Check that the IR camera is in null mode p 19 2 Press the S key then the image is freezing 3 Press the S key again then the image is active ww...

Страница 39: ...the MENU ENTER key 3 Press UP or DOWN arrow on the omni selector to select Object Para then press the MENU ENTER key 4 Setting analysis parameter Press the UP or DOWN arrow on theomni selector to sele...

Страница 40: ...different distance to measure different object Amb Temp Input ambient temperature Humidity Input ambient humidity Comp Obj Comp Obj1 can be set as any spot and area Comp Obj2 can be set as ref temp a...

Страница 41: ...41 Reading www GlobalTestSupply com Quality SATIR Products Online at sales GlobalTestSupply com...

Страница 42: ...ctor to select Analysis Setup then press the MENU ENTER key 4 Setting analysis parameter Press the UP or DOWN arrow on theomni selector to select anitem to change Press the LEFT or RIGHT arrow on the...

Страница 43: ...the value you set in alert temp the reading on top right screen will turn into RED and also sound of beepin Note select spot analysis tools capture max capture min in menu Analysis Alert Temp Sets the...

Страница 44: ...n the upper limit of the isothermal interval in the same color Below Display the isothermal interval and the parts with the lower temperature than the lower limit of the isothermal interval in the sam...

Страница 45: ...e UP or DOWN arrow on the omni selector to select the Spot menu 4 Setting the spot analysis Press the UP or DOWN arrow on the omni selector to select a spot then press MENU ENTERKey Spot 10 will autom...

Страница 46: ...ot Temperature reading of spot changes in real time 6 Removing the spot Start from Step 1 to set or select an analysis spot Press C key to remove the spot E8 N has only one analysis spot E8 TN has fou...

Страница 47: ...e omni selector to select aarea then press MENU ENTERKey One or more box will appear on the screen A reading will appear at the top right corner It is the reading of the highest lowest average tempera...

Страница 48: ...IGHT arrow on the omniselector to move the activated area Temperature readingchanges in real time 6 Removing the area Start from Step 1 to set or select an area analysis Press C key to remove the acti...

Страница 49: ...rrow LOWER and RIGHT arrow E8 N and E8 TN don t have the area analysis function so you won t see the Area item in their analysis menu www GlobalTestSupply com Quality SATIR Products Online at sales Gl...

Страница 50: ...4 Moving the profile analysis Start from Step 1 to set or select a profile analysis Press the UP DOWN arrow on the omni selector to move the profile 5 Removing the profile analysis Start from Step 1...

Страница 51: ...g isotherm range Start from Step 1 to set or select isotherm analysis Press the UP or DOWN arrow on the omni selector to select isotherm range IL and IH will appear at the bottom right corner It is th...

Страница 52: ...to select the Analysis menu 3 Press the UP or DOWN arrow on the omni selector to select Remove Spot Press the LEFT or RIGHTarrow on the omni selector to select to remove all the spots areas profile or...

Страница 53: ...y 2 Press the UP or DOWN arrow on the omni selector to select the File menu 3 Press UP or DOWN arrow on the omni selector to select Save then press the Menu Enter key to save the image The display mod...

Страница 54: ...UP or DOWNarrow on the omni selector to select the File menu 4 Press UP or DOWN arrow on the omni selector to select Voice REC then press the Menu Enter key The Voice Recording message will appear on...

Страница 55: ...le trigger Lighting on You can activate the illuminatorby pressing the trigger You can get clear visible images in darkness when you turn on the illuminator Save File Save the image by pressing the tr...

Страница 56: ...56 E8 N is not equipped with laser and illuminator www GlobalTestSupply com Quality SATIR Products Online at sales GlobalTestSupply com...

Страница 57: ...mni selector to select Open then press the MENU ENTERkey 4 Press LEFT or RIGHT arrow on the omni selector to select an image then press MENU ENTER key to open it How to select an image refer to p 54 Y...

Страница 58: ...n the current folder press the LEFT or RIGHT arrow on the omni selector repeatlyto select the image 3 Press the S key you can activate the image 00001 00003 002 003 DIR GZSAT001 Open SAT00001 SAT File...

Страница 59: ...enu then press the MENU ENTER key 4 Press the UPorDOWN arrow on the omni selector to select the Directory Name menu then press the LEFTorRIGHT arrow to select the folder File number is the number of f...

Страница 60: ...R key then press UPorDOWN arrow on the omni selector to select the File menu 4 Press UPorDOWN arrow on the omni selector to select Voice Play then press the Menu Enter key A Playing Record message wil...

Страница 61: ...press UPorDOWN arrow on the omni selector to select the File menu 2 Press UPorDOWN arrow on the omni selector to select Delete then press the MENU ENTER key 3 Select an image refer to p 54 then press...

Страница 62: ...images to the computer via the supplied SD card reader 1 Open the battery SD card cover 2 Press the SD card lightly then the SD card will pop up automatically 3 You can download the IR images via the...

Страница 63: ...pen the battery SD card cover in the direction of the arrow 2 Lay the dock on a horizontal flat then put the camera on the dock in the direction of the arrow Press the camera gently down to the dock i...

Страница 64: ...ti functional dock 2 3 Attachthe power cord to the dock and plug the other end into a power outlet 4 The power LED of camera flickers while the battery pack is charging and it lights green when chargi...

Страница 65: ...lied can be used to view and analyze images you shoot 1 Attach video cable to the video out terminal on the multi functional dock 2 Plug the other end of the video cable to the video in jack on the mo...

Страница 66: ...8 GN has the USB function You do not need to turn off the computer or camera when making this connection Please refer to your computer manual for information regarding the location of the USB port The...

Страница 67: ...disk optional to the CD ROM driver UsersofWindowsXPProfessionalmustfirstloginasanAdministrator computersystemadmi nistrator toinstallprogram 1 After a few moments the following dialog will appear 2 S...

Страница 68: ...rowse Locate the directory of the driver and click Ok to return to the previous window Then click Next 5 Click ContinueAnyway 6 Click Finish to finish the driver installation www GlobalTestSupply com...

Страница 69: ...connect the camera and the dock p 59 2 Connect the dock and computer via USB cable optional p 62 3 The operation system will recognize the camera after install the driver p 61 4 You can analyze the r...

Страница 70: ...62forconnectioninstructions 3 Isthebatterychargedsufficiently Youshoulduseahouseholdpowersourcetopowerthecamerawheniti s connectedtoacomputer IftheProblemIsNotMentionedAbove IftheUSBDriverisnotcorrect...

Страница 71: ...e indicator flashes at the same time In this mode camera is preparing to pair the Bluetooth headset 4 Press the power button of Bluetooth headset to pair the headset and camera When the pairing is suc...

Страница 72: ...Enter key together to free the Bluetooth headset 6 Wear the headset you can record the vioce memos p 51 or play back the memos p 56 now Bluetooth headset is not the standard accessory of E8 N and E8...

Страница 73: ...sun shield when you are shooting outdoors in the sun 1 Install the sun shield inthe direction of the arrow by followintg the below guide 2 Use the sun shield www GlobalTestSupply com Quality SATIR Pr...

Страница 74: ...as follow 2 Set up the measurement range Press UP and Down key on the arrow at the same time to change to type of lens p 36 Refer to the below table to see what type of lens the letterstands for Type...

Страница 75: ...orrectly Format the internal memory in FAT32 format Battery pack consumed quickly Battery pack capacity reduced because of disuse for one year or more after being fully charged Replace the battery pac...

Страница 76: ...se synthetic cleaners on the camera body or lens LCD monitor Use a lens blower brush to remove dust and dirt If necessary gently wipe the LCD monitor with soft cloth or an eyeglass lens wiper to remov...

Страница 77: ...ina 25 600 0 10 0 20 Strong alumina 25 600 0 30 0 40 Brass Brass mirror highly polished 28 0 03 Brass oxide 200 600 0 61 0 59 Chrome Polished chrome 40 1090 0 08 0 36 Copper Copper mirror 100 0 05 Str...

Страница 78: ...plate 100 0 74 Oxidized steel 198 600 0 64 0 78 Cast iron Oxidizing at 600 C 198 600 0 79 Steel Oxidizing at 600 C 125 520 0 78 0 82 Electrolytic ferric oxide 500 1200 0 85 0 89 Iron plate 925 1120 0...

Страница 79: ...polishing 25 0 05 Electroplate 20 0 01 non polishing Nickel wire 185 1010 0 09 0 19 Nickel plate oxidized 198 600 0 37 0 48 Nickel oxide 650 1255 0 59 0 86 Nickel alloy Nickel chrome heat resistance a...

Страница 80: ...ion 0 200 0 60 Zinc Oxidizing at 400 C 400 0 01 galvanized shining iron plate 28 0 23 Ash zinc oxide 25 0 28 Non metal materials Brick 1100 0 75 Fire brick 1100 0 75 Graphite lamp black 96 225 0 95 Po...

Страница 81: ...n enamel designs 0 83 0 95 Solid materials 0 80 0 93 Ceramics vase type 0 90 Film 0 90 0 93 Mica 0 94 0 95 Flume mica 0 90 0 93 Glass 0 91 0 92 Semiconductor 0 80 0 90 Transistor plastics sealed 0 30...

Страница 82: ...Electric materials Epoxy glass plate 0 86 Epoxy hydroxybenzene plate 0 80 Gilded sheet copper 0 30 Solder coated copper 0 35 Tin coated lead wire 0 28 Brass wires 0 87 0 88 Block talcum terminal 0 87...

Страница 83: ...mal Visible DuoVision Fusion No Yes Yes Image Annotation No No Voice Annotation Display 2 5 TFT Screen Visible Light Camera Resolution 640 x 480 Full color Measurement Temperature Range 20 C 250 C Acc...

Страница 84: ...F to 122 F Storage Temperature Range 40 C to 70 C 40 F to 158 F Humidity 95 relative humidity 25 C to 40 C 77 F to 104 F non condensing Encapsulation IP54 Shock Vibration 25G 2G Physical Characterist...