background image

PRODUCT INFO

25.04.2000

SATEL Oy, P.O.Box 142, FIN-24101 Salo, Finland

Street: Meriniitynkatu 17, FIN-24100 Salo, Finland

Tel: +358 2 777 7800, Fax: +358 2 777 7810, E-mail: 

[email protected]

www.satel.fi

Setting of Port2 / Switch Positions

SW 1

SW 2

SW 3

SW 4

SW 5

SW 6

SW 7

SW 8

SW 9

SW 10

SW 8

RS-232

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

RS-485/422

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

# Switches 1 to 5 are for setting of the Port2. Switches 6 to 8 are for software boot loading. Switches 9 and 10 are not in use.

 

Close the radio modem carefully. Please note that the four screws of the back cover of 3ASd are

not equally long. The shorter ones have to be mounted to the antenna side. Longer screws break

the display if mounted to the wrong holes.

 

Enter to the setup mode according to the user´s guide.

 

Type * (=asterisk) for to enter the factory setup menu

 

Change the setting of the Port2 to the correct value (same as the switches)

 

Return to the main menu and check all the other settings to be as required.

 

Exit the setup mode

Please note that the warranty of the radio modem will expire if the device has been opened by

unauthorised person.

• Other port settings

For Satelline-3AS(d) radio modem the following serial port settings have to be defined for proper data

communication.

Data speed

Data speed at serial port is selectable from 300 up to 38400 bps. Bit rate

over the air is constant and depends only on the channel spacing, i.e.

9600 bps for 12.5 kHz, and 19200 bps for 25 kHz. 3AS(d) link may act

as a data speed converter in the system. Data speed can be set to a

different value at the ends of the link.

Number of data bits

7, 8 or 9

Parity

None, Even or Odd

Number of stop bits

1 or 2 Start, stop and parity bits are not transferred via the radio. They are

generated at the other end according to the serial port settings.