65
SATEL OY
// SATELLAR MANUAL // RADIO UNIT // USER GUIDE // V. 1.8
10. Troubleshooting
3
Name
Description
Code
LED Required action
ERROR_CAT_PLL_LOCK
The RF frequency
synthesizer has not
been locked and
either transmission or
reception is not possible.
0 1000
(8)
•
•
•
•
•
•
•
•
Reboot the unit. If the problem
remains the unit should be sent to
service.
ERROR_CAT_RAM_
CHECK
RAM memory
verification failed during
initialization.
0 1001
(9)
•
•
•
•
•
•
•
•
Reboot the unit. If the problem
remains the unit should be sent to
service.
ERROR_CAT_SW_
FAILURE_1
Watchdog originated
reboot because of a SW
crash
0 1010
(10)
•
•
•
•
•
•
•
•
No actions required. If the same
happens repeatedly the unit should be
sent to service.
ERROR_CAT_SW_
FAILURE_2
The SW has recognized
an error and gone into
error state
0 1011
(11)
•
•
•
•
•
•
•
•
Reboot the unit. If the problem
remains the unit should be sent to
service.
ERROR_CAT_NVM_
COMM
No access to the non-
volatile memory
0 1100
(12)
•
•
•
•
•
•
•
•
Reboot the unit. If the problem
remains the unit should be sent to
service.
ERROR_CAT_NVM_
UNINITIALIZED
Non-volatile memory
has entered an
unformatted state due to
an internal error.
0 1101
(13)
•
•
•
•
•
•
•
•
Reboot the unit. If the problem
remains the unit should be sent to
service.