4
RX-2K • RX-4K
SATEL
5.1 Preparation for configuring using the DLOAD10 program
Connecting the computer to the controller
To make the connection, use the USB-RS converter offered by SATEL. The controller has no
RS port connector, therefore you must use the PIN3/RX adapter, which is delivered with the
converter. Screw the adapter wires to the controller terminals in accordance with Table 1 and
Fig. 2.
Wire color
Function
Terminal
green
Rx signal
AL
white
Tx signal
LV
black
common ground
COM
Table 1.
Notes:
If you cannot establish communication between the controller and the program, add
a 47 k
Ω
resistor between the LV and +12V terminals.
Before connecting the adapter wires to the AL and LV terminals, disconnect other wires
from these terminals.
Fig. 2. Connecting the PIN3/RX adapter to the controller.
- green wire – screw it to AL
terminal.
- white wire – screw it to LV terminal.
- black wire – screw it to COM
terminal.
Starting communication between the controller and the program
1. Run the DLOAD10 program. Access to the program is protected by a password. To obtain
access at the first run of the program, enter the factory default password: 1234 (you need
not enter the factory password, just click “OK”).
2. Click “Communication”
“Configuration”. The “Configuration” window will be displayed.
3. In the “Port RS-232” field, select the computer COM port to be used for communication
with the controller.
4. Click “OK”.
5. Press and hold down the PRG2 [RX-2K] / PRG4 [RX-4K] controller button.
6. After the LED flashes red once, release the button.